Extender Drug Eluting PTCA Balloon Catheters
Engineered with advanced drug-coating technology, ensuring uniform and
controlled drug delivery to the vessel wallOptimally designed for precise lesion dilation while minimizing vessel wall trauma,
providing therapeutic advantages in challenging scenarios
Precision Treatment, Exceptional Results
Drug incorporated in hydrophilic coating
Hydrophilic coating delivers Paclitaxel homogeneous to the vessel wall instantaneously upon contact
No airborne particles at any time and no premature release of Paclitaxel
Paclitaxel is only released when the balloon touches the vessel wall
Elevating PTCA to New Heights
No longitudinal growth for controlled expansion, even at high pressures
No balloon deformations up to rated burst pressure for precise stent apposition
Rapidly and maximally absorbed by the vessel wall
Minimized drug loss in bloodstream prior to inflation securing reliable drug dose delivery
Load secured to achieve the therapeutic window within 30 seconds inflation time
providing an extensive and safe working range
By choosing the Extender Drug-Eluting PTCA Balloon, healthcare professionals are not just choosing a device; they are choosing a solution that brings together the best in medical engineering and pharmacology to provide a comprehensive treatment option. With the Extender Balloon, patients are in good hands, and surgeons are equipped to deliver exceptional care.
EFFORTLESS DELIVERABILITY
By choosing the Extender Drug-Eluting PTCA Balloon, healthcare professionals are not just choosing a device; they are choosing a solution that brings together the best in medical engineering and pharmacology to provide a comprehensive treatment option. With the Extender Balloon, patients are in good hands, and surgeons are equipped to deliver exceptional care.
Proven efficacy in inhibiting restenosis, backed by robust clinical evidence and favorable outcomes
No procedural limitations
No change in standard operating procedures and no handling required
No pre-dilatation required: Lesion crossing does not influence drug delivery
Multiple inflations will not lead to toxic levels
Therapeutic window achieved after 30 seconds inflation time
Flexibility and characteristics of a normal workhorse PTCA balloon
Highly compliant balloon material ensures optimal contact with the vessel wall for effective drug delivery.
Paclitaxel Drug Coating
Localized Drug Delivery: The balloon’s 3.0–3.5 µg/mm² paclitaxel formulation aims to inhibit neointimal hyperplasia, reducing the risk of recurrent stenosis.
Optimized Release Profile: Ensures adequate drug transfer upon inflation, without prolonged systemic exposure.
Balloon Dimensions and Range
Balloon Diameters: 2.0 mm to 5.0 mm, covering small vessel and large coronary segment needs.
Balloon Lengths: 10, 15, 17, 20, 26, and 30 mm, offering tailored lesion coverage based on vessel size and lesion extent.
Rapid Exchange (RX) Shaft Design
Easy Wire Management: Facilitates quick guidewire exchanges and precise navigation in branch or distal lesions.
Catheter Lengths: 120 cm and 150 cm, adapting to various patient anatomies or access routes (radial/femoral).
Radiopaque Markers
RO Marker Bands: Enhance fluoroscopic visibility, aiding in accurate balloon positioning and monitoring during inflation.
Guidewire Compatibility
0.014” Standard: Ensures broad usage with common PCI guidewires, promoting smooth device transitions.
Localized Drug Delivery: The balloon’s 3.0–3.5 µg/mm² paclitaxel formulation aims to inhibit neointimal hyperplasia, reducing the risk of recurrent stenosis.
Optimized Release Profile: Ensures adequate drug transfer upon inflation, without prolonged systemic exposure.
Balloon Diameters: 2.0 mm to 5.0 mm, covering small vessel and large coronary segment needs.
Balloon Lengths: 10, 15, 17, 20, 26, and 30 mm, offering tailored lesion coverage based on vessel size and lesion extent.
Easy Wire Management: Facilitates quick guidewire exchanges and precise navigation in branch or distal lesions.
Catheter Lengths: 120 cm and 150 cm, adapting to various patient anatomies or access routes (radial/femoral).
RO Marker Bands: Enhance fluoroscopic visibility, aiding in accurate balloon positioning and monitoring during inflation.
0.014” Standard: Ensures broad usage with common PCI guidewires, promoting smooth device transitions.