Skip to main content
INVAMED

Large-lumen aspiration thrombectomy catheter for rapid clot extraction in acute DVT, PE, and arterial thromboembolism with minimal fragmentation.

Last Updated: July 2026

Dovi Thrombus Ultra Aspiration Catheter

Dovi Thrombus Ultra Aspiration Catheter

A high-vacuum aspiration catheter for acute or subacute thrombus removal in arterial or venous beds, ensuring rapid revascularization with minimal fragmentation risk.

Specialties

Venous

The Dovi ThromboJET Aspiration System is a cutting-edge device that combines efficient thrombus aspiration with minimal kinking and superior crossing capability. By leveraging a powerful yet oil-free diaphragm pump and a well-designed aspiration catheter, Dovi aims to streamline clot removal in acute, complex, and challenging vascular occlusions—offering clinicians a fast and minimally invasive method to restore perfusion and improve patient outcomes.

Optimized Crossing Efficiency

  • Low-Profile Catheter Shaft: Engineered for navigating tortuous anatomies or calcified segments, ensuring stable trackability and minimal friction.

  • Kink-Resistant Construction: Maintains lumen patency under dynamic maneuvers, supporting effective aspiration even in tight or angled vessel pathways.

Robust Thrombus Aspiration

  • High-Vacuum Pump: An adjustable vacuum range of 80–550 mmHg empowers operators to select the optimal suction force for diverse clot consistencies.

  • Enhanced Thrombectomy: Rapid removal of thrombus and debris, potentially reducing ischemic time and lowering the risk of distal embolization.

Ergonomic and Versatile Design

  • Compact Footprint: Measuring 18 × 23 × 20 cm and weighing only 1.7 kg (excluding adapter), the Dovi system suits various clinical settings, from catheter labs to hybrid operating rooms.

  • Disposable Collection Container (800 mL): Simplifies disposal, maintains sterility, and minimizes cross-contamination risk.

Consistent, Oil-Free Operation

  • Diaphragm Pump Technology: Eliminates the complexities and potential contamination risks of oil-based vacuum pumps.

  • Battery Capacity (60 min): Provides backup power for short procedures or in unstable power environments, ensuring continuous aspiration when time is critical.

  • Low-Profile Catheter Shaft: Engineered for navigating tortuous anatomies or calcified segments, ensuring stable trackability and minimal friction.

  • Kink-Resistant Construction: Maintains lumen patency under dynamic maneuvers, supporting effective aspiration even in tight or angled vessel pathways.

  • High-Vacuum Pump: An adjustable vacuum range of 80–550 mmHg empowers operators to select the optimal suction force for diverse clot consistencies.

  • Enhanced Thrombectomy: Rapid removal of thrombus and debris, potentially reducing ischemic time and lowering the risk of distal embolization.

  • Compact Footprint: Measuring 18 × 23 × 20 cm and weighing only 1.7 kg (excluding adapter), the Dovi system suits various clinical settings, from catheter labs to hybrid operating rooms.

  • Disposable Collection Container (800 mL): Simplifies disposal, maintains sterility, and minimizes cross-contamination risk.

  • Diaphragm Pump Technology: Eliminates the complexities and potential contamination risks of oil-based vacuum pumps.

  • Battery Capacity (60 min): Provides backup power for short procedures or in unstable power environments, ensuring continuous aspiration when time is critical.