"(《世界人权宣言》) King Vascular Revascularization Device 是一个 stent-based retrieval system designed to restore cerebral blood flow in patients presenting with acute ischemic stroke due to large intracranial vascular occlusion. Incorporating overlapping stent technology, King Vascular effectively captures 和 removes thrombus while reinvigorating cerebral perfusion—making it a rapid 和 创新的 approach for neurovascular revascularization.
					 Overlapping Stent Construction
						
- Enhanced Clot Capture: The device’s multi-layer stent struts increase contact with thrombus, improving retrieval efficacy in large or tough clots.
 - Optimized Vessel Conformability: Overlapping cells allow the stent to adapt closely to the tortuous geometry of intracranial arteries, ensuring stable engagement throughout the retrieval process.
 
					 Neurovasculature Compatibility
						
- Broad Anatomical Coverage: Suitable for the internal carotid artery (ICA), M1/M2 segments of the middle cerebral artery, basilar和 vertebral arteries.
 - Dedicated Neurovascular Materials: Constructed to retain flexibility in smaller-caliber and curved intracranial vessels, reducing the risk of vessel trauma during navigation and retrieval.
 
					 Rapid & Innovative Clot Retrieval
						
- Seamless Deployment: Designed for rapid insertion and retrieval under fluoroscopic guidance, decreasing overall device manipulation.
 - High Visibility Markers: Radiopaque markers along the stent struts ensure precise positioning and real-time feedback under angiography.
 
					 Flow Restoration
						
- Improved Patency: The stent lattice temporarily expands the occluded segment, promoting partial or complete flow restoration even before full clot retrieval.
 - Multiphase Extraction: Operators can perform multiple passes if needed, targeting residual thrombus while maintaining cerebral perfusion.
 
- Enhanced Clot Capture: The device’s multi-layer stent struts increase contact with thrombus, improving retrieval efficacy in large or tough clots.
 - Optimized Vessel Conformability: Overlapping cells allow the stent to adapt closely to the tortuous geometry of intracranial arteries, ensuring stable engagement throughout the retrieval process.
 
- Broad Anatomical Coverage: Suitable for the internal carotid artery (ICA), M1/M2 segments of the middle cerebral artery, basilar和 vertebral arteries.
 - Dedicated Neurovascular Materials: Constructed to retain flexibility in smaller-caliber and curved intracranial vessels, reducing the risk of vessel trauma during navigation and retrieval.
 
- Seamless Deployment: Designed for rapid insertion and retrieval under fluoroscopic guidance, decreasing overall device manipulation.
 - High Visibility Markers: Radiopaque markers along the stent struts ensure precise positioning and real-time feedback under angiography.
 
- Improved Patency: The stent lattice temporarily expands the occluded segment, promoting partial or complete flow restoration even before full clot retrieval.
 - Multiphase Extraction: Operators can perform multiple passes if needed, targeting residual thrombus while maintaining cerebral perfusion.
 
产品规格
| 规格 | 细节/价值 | 
| 产品名称 | KinG 颅内血管重建装置 | 
| 预期用途 | Acute ischemic stroke treatment in large vessel occlusion (LVO), mechanical thrombectomy within intracranial arteries | 
| Device Type | Stent retriever or revascularization device with self-expanding design | 
| 材料 | Medical-grade nitinol (Nickel-Titanium) or cobalt-chromium alloy | 
| 部署机制 | Microcatheter-based insertion, typically 0.021”–0.027” ID | 
| 不透射线标记 | Distal and proximal markers for fluoroscopic visualization | 
| Length & Diameter Range | ~15–40 mm length, 3–6 mm diameter (depending on specific code) | 
| 兼容性 | Guide catheter or sheath (≥ 5F–6F) for intracranial access, 0.014” wire guidance | 
| 无菌 | 无菌,一次性使用 | 
| 保质期 | ~3–5 years at 15–25 °C in sealed packaging | 
| 临床适应症 | Large vessel occlusion in the anterior or posterior circulation, e.g., M1, M2, ICA terminus, basilar artery | 
| 禁忌症 | Extreme vessel tortuosity, advanced intracranial stenosis, known nickel allergy | 
订购和尺寸表
| Device Diameter (mm) | Device Length (mm) | Microcatheter ID (inch) | 产品代码 | 说明 | 
| 3.0 | 20 | 0.021" | KNG-3.0x20-021 | Smaller stent retriever for distal M2 or narrower vessels | 
| 3.0 | 28 | 0.021" | KNG-3.0x28-021 | Extended length, same diameter | 
| 4.0 | 20 | 0.021" | KNG-4.0x20-021 | Mid-range diameter, short retriever for M1 | 
| 4.0 | 28 | 0.027" | KNG-4.0x28-027 | Longer device, larger microcatheter needed | 
| 4.5 | 28 | 0.027" | KNG-4.5x28-027 | Wider diameter for proximal ICA or large M1 | 
| 4.5 | 35 | 0.027" | KNG-4.5x35-027 | Extended coverage in wide vessel occlusions | 
| 6.0 | 40 | 0.027" | KNG-6.0x40-027 | Largest diameter for basilar tip or wide ICA | 
				