Stena 頭蓋内多層フローモジュレーター

A 多層 のための流れ分岐コンストラクト 頭蓋内動脈瘤動脈瘤嚢から血流を遠ざけると同時に、必要不可欠な枝の灌流を維持する。

について Stent Neurovascular Multilayer Flow Modulatormulti-layer, self-expandable implant designed to redirect blood flow across intracranial aneurysms or pseudoaneurysms (saccular, fusiform, or dissection). Constructed from nitinol braided wires, this flow-guided device harnesses hemodynamic modulation to promote stable aneurysm occlusion while preserving key vessel branches.

Multi-Layer Braided Nitinol Wires
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring 精密 navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring 精密 navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.

製品仕様

仕様 詳細 / 価値
製品名 Stena 頭蓋内多層フローモジュレーター
使用目的 Endovascular flow diversion for intracranial aneurysms (saccular, fusiform) or complex neurovascular lesions
デザイン Multi-layer braided nitinol mesh stent, self-expanding, designed to modulate blood flow while preserving side branches
素材 Medical-grade Nitinol (Nickel-Titanium)
展開メカニズム Sheath-based retraction or microcatheter system release
Delivery Catheter Compatibility Typically 0.027” or 0.021” ID microcatheter (depending on stent diameter)
放射線不透過性マーカー Proximal and distal marker bands for fluoroscopic positioning
MRの互換性 MR Conditional (verify labeling)
不妊症 滅菌済み、シングルユース
賞味期限 ~3–5 years, stored at 15–25 °C in sealed packaging
臨床適応症 Intracranial aneurysms (small or large/giant), dissecting or fusiform aneurysms, flow diversion in distal vessels
禁忌事項 Extremely tortuous intracranial vessels beyond feasible access, known nickel allergy, insufficient landing zone

オーダー&サイズマトリックス

Stent Diameter (mm) Stent Length (mm) Microcatheter ID (inch) 商品コード 備考
2.5 12 0.021" STN-IC-2.5x12-021 Smaller diameter, short aneurysm coverage
2.5 18 0.021" STN-IC-2.5x18-021 Extended length for multiple side branches
3.0 18 0.027" STN-IC-3.0x18-027 Common diameter for medium intracranial vessels
3.0 25 0.027" STN-IC-3.0x25-027 Longer stent for extended aneurysm neck
3.5 20 0.027" STN-IC-3.5x20-027 Slightly larger diameter for wide-neck aneurysms
3.5 30 0.027" STN-IC-3.5x30-027 Extended coverage in more proximal segments
4.0 20 0.027" STN-IC-4.0x20-027 Larger diameter for cavernous ICA aneurysms
4.0 30 0.027" STN-IC-4.0x30-027 Extended length for giant aneurysm coverage
4.5 25 0.027" STN-IC-4.5x25-027 XL diameter for large internal carotid segments
4.5 35 0.027" STN-IC-4.5x35-027 Maximum coverage for fusiform or dissecting lesions