Filler シアノアクリレート系塞栓剤
A シアノアクリレート 塞栓用接着剤 血管 または 属性値 閉塞感、提供 迅速 血液と接触すると重合し、安定した血管密封と最小限のアーチファクトを確保する。
Rapid and Reliable Embolization for Critical Moments
- The Filler Cyanoacrylate-Based Embolization Agent is distinguished by its rapid polymerization and targeted application, ensuring immediate and reliable vessel occlusion.
- Filler works by causing an inflammatory reaction over the endothelium of the target vein upon the injection of the polymer and simultaneous pressure application.
Secure Occlusion, Superior Outcomes
- Its high-viscosity formulation and compatibility with standard catheters enhance control during application, minimizing the risk of non-target embolization.
- Filler was developed for the treatment of peripheral and neurovascular, including arteriovenous malformations and hypervascular tumors by a simple polymerization method.
- Small amounts of polymer were delivered endovenous and pressure of up to 2-3 minutes to applied for total closure.

CAN BE
PERFORMED
SAFELY
Filler: Precision Embolization, Promising Results
Designed for biocompatibility, Filler minimizes inflammatory responses post-embolization, promoting patient safety and recovery. Choose Filler for a cutting-edge embolization solution that delivers superior outcomes and sets the standard in vascular care.
- Agent Type: Cyanoacrylate-based embolization agent.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
- Mechanism of Action: Rapid polymerization upon contact with ionic substances such as blood, leading to instant vessel occlusion.
- Indications: Suitable for arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization.
- Application: Delivered through standard catheters, allowing for precise application and minimization of non-target embolization.
- Biocompatibility: Designed to be biocompatible and minimize inflammatory responses post-embolization.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
FAST
EFFECTIVE
& EASY
Filler Cyanoacrylate-Based Embolization Agent stands out as a cutting-edge solution for targeted and rapid vascular occlusion. Its high-viscosity liquid form, comprised of cyanoacrylate, is expertly designed to ensure controlled application and immediate results.
Upon contact with ionic substances such as blood, Filler rapidly polymerizes, leading to instant and durable vessel occlusion. This makes it an ideal choice for critical applications such as arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization. Its delivery through standard catheters ensures precise application, reducing the risk of non-target embolization and enhancing procedural success.

- Neuro Aneurysms and AVMs
- Abdominal Aneurysms, Endoleaks
- Neurovascular & Peripheral Aneurysms and AVMs
- Short procedure procedure time.
- Mix with lipiodol for radiopacity
Filler is delivered through a microcatheter into the AVM under fluoroscopic control.
Filler immediately forms a skin as the polymeric embolus solidifies from the outside to the inside, while traveling more distally in the vessel.
Type 2 endoleak from lumbar arteries. (A) Computed tomography (CT) scan in the procubitus position shows posterior opacification of the periprosthetic aneurysmal sac (nidus). (B) Embolization of the endoleak center with a microcatheter under CT guidance until nidus opacification is complete.
製品仕様
仕様 | 詳細 / 価値 |
製品名 | Filler Cyanoacrylate Embolization Agent |
使用目的 | Embolization of AVMs, fistulas, varices, or other lesions requiring permanent vascular occlusion |
Composition | n-Butyl or n-Hexyl cyanoacrylate formulation, polymerizes rapidly upon contact with blood/tissue |
Polymerization Mechanism | Instant polymerization triggered by ionic/aqueous environment |
Delivery Method | Via microcatheter (coaxial with DMSO or compatible flushing agent, if needed) |
ラジオパシティ | May require added radiopaque contrast (e.g., Lipiodol) for fluoroscopic visibility |
Viscosity | Low to medium (check final specs), allowing controlled injection time |
不妊症 | 滅菌済み、シングルユース |
賞味期限 | ~密封包装で15~25℃にて~2~3年 |
臨床適応症 | Neurovascular or peripheral AVM occlusion, gastrointestinal bleeders, variceal management, certain tumor devascularizations |
禁忌事項 | Vessel lumens too small for catheter access, potential risk if accidental nontarget injection, known allergy to cyanoacrylates |
オーダー&サイズマトリックス
Cyanoacrylate Concentration (%) | Vial Volume (mL) | Recommended Mixing Ratio | 商品コード | 備考 |
33 | 1.0 | 1:1 with radiopaque agent | FIL-33-1.0-1:1 | Lower concentration, slower polymerization, suitable for distal lesions |
33 | 2.0 | 1:1 | FIL-33-2.0-1:1 | Larger vial, same concentration |
50 | 1.0 | 1:0.5 | FIL-50-1.0-1:0.5 | Faster set time, moderate volume |
50 | 2.0 | 1:0.5 | FIL-50-2.0-1:0.5 | Larger volume for multiple feeders |
67 | 1.0 | 1:0.25 | FIL-67-1.0-1:0.25 | High concentration, rapid polymerization for high-flow lesions |
67 | 2.0 | 1:0.25 | FIL-67-2.0-1:0.25 | Maximum control in large or complex AVMs |
関連商品
-
MicroDELIVERY塞栓用カテーテル
続きを読むに最適化されたマイクロカテーテルである。 精密 塞栓剤を細い血管領域や遠位血管領域に送達することで、均一な分布と最小限の逆流を確保する。
-
Stena 大動脈マルチレイヤー・フローモジュレーター
続きを読む専門的な 多層ステント に設計されている。 大動脈の流れを調整する動脈瘤の灌流を阻害することなく、嚢圧を低下させ、動脈瘤を安定化させる。の血行動態を再構築するように設計されている。 胸部または腹部大動脈 病変の長期予後を改善する。
-
Spider™ 頭蓋内コイルシステム(着脱式プッシャブル)
続きを読むA 着脱式コイルシステム にとって 頭蓋内 または ペリフェラル 動脈瘤のコイリングは、即座に機械的に剥離することが特徴である。 最適化された 容積パッキン。
-
VeinOFF 静脈瘤治療剤
続きを読む専門的な 硬化剤 または 接着剤 を目指した処方である。 非熱 静脈瘤の除去には、最小限の麻酔と短い処置時間が必要です。