AngioHAND 血栓除去カテーテル
A ハンドマニピュレーテッド 機械式吸引装置により、即時吸引が可能 血餅抽出 を経由する。 マニュアル バキュームアプローチにより、急性血栓除去術が簡略化される。
The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.
Braided Balloon-Shaped Capture
- Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
- Ensures robust clot entrapment without excessive fragmentation or distal embolization.
Manual Vacuum Mechanism
- Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
- Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
Rapid & Intuitive Thrombectomy
- Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
- One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
Enhanced Safety & Vessel Protection
- Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
- Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
Multiple Clinical Indications
- Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
- Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
- Use in emergent or elective procedures where fast mechanical clot extraction is paramount.
製品仕様
仕様 | 詳細 / 価値 |
製品名 | AngioHAND 血栓除去カテーテル |
使用目的 | Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels |
カテーテルのデザイン | Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip |
外径範囲 | ~5F–7F (depending on model) |
Lumen Inner Diameter | Large bore optimized for clot aspiration |
作業長 | ~80–120 cm (varies by product code) |
チップ構成 | Tapered or funnel-shaped tip to facilitate clot ingress |
Radiopaque Marker | Distal marker band for fluoroscopic location |
Vacuum Mechanism | Manual hand-syringe or integrated vacuum lock (no external pump required) |
不妊症 | 滅菌済み、シングルユース |
賞味期限 | ~2–3 years at 15–25 °C |
臨床適応症 | Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts |
禁忌事項 | Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy |
オーダー&サイズマトリックス
外径(F) | 作業長 (cm) | 先端スタイル | 商品コード | 備考 |
5F | 80 | Tapered Soft Tip | ANG-HND-5F-80-TS | Smaller diameter for coronary or distal peripheral |
5F | 100 | Funnel Tip | ANG-HND-5F-100-FN | Moderate length, manual vacuum approach |
6F | 80 | Tapered Soft Tip | ANG-HND-6F-80-TS | Common size for peripheral thrombus aspiration |
6F | 120 | Funnel Tip | ANG-HND-6F-120-FN | Extended length for deeper occlusion sites |
7F | 100 | Tapered Soft Tip | ANG-HND-7F-100-TS | Larger lumen for heavier clot burden |
7F | 120 | Funnel Tip | ANG-HND-7F-120-FN | Maximum length plus funnel design for wide clot removal |
関連商品
-
Atlas静脈ステント
続きを読む生体適合性のある金属合金でできた特殊なインプラントシステムで、血管の開存性を維持し、血流を改善し、慢性静脈不全の症状を緩和することによって静脈閉塞を治療するように設計されている。
-
Dovi 血栓超吸引カテーテル
続きを読むA 高真空 吸引カテーテル 切実 または 亜急性 動脈または静脈床の血栓を除去し、断片化のリスクを最小限に抑えながら迅速な血行再建を可能にする。
-
LaserBLOCK 下肢静脈瘤レーザーシステム