的 PetaⓇ Sternum Closure Plate addresses the challenges associated with fixating a 90-degree sternal incision or rib osteotomy through an anatomically contoured, low-profile design. Constructed from a highly biocompatible Ti-6Al-4V-ELI alloy and featuring a user-friendly locking block, PetaⓇ provides secure and re-tensionable closure, ensuring optimal stability and patient comfort.
Low-Profile Design
- Minimally Invasive Access: The plate’s thin profile accommodates incisions in tight anatomical spaces, lessening postoperative discomfort and risk of soft tissue irritation.
- Anatomical Contouring: Engineered to conform seamlessly to the curvature of the sternum or rib, enhancing implant stability while preserving natural bone alignment.
Locking Block with Ti-6Al-4V-ELI Alloy
- Highly Biocompatible: The titanium alloy demonstrates excellent osseointegration and minimal inflammatory response, making it suitable for long-term surgical implants.
- Secure Lock Mechanism: Once fixed by the locking-block screw, there is no risk of self-loosening or accidental opening—critical for maintaining consistent compression across the osteotomy site.
- Re-Tension Capability: The locking block screw can be loosened intraoperatively to re-tension the plate, streamlining adjustments and shortening operating room time.
- Secure Lock Mechanism: Once fixed by the locking-block screw, there is no risk of self-loosening or accidental opening—critical for maintaining consistent compression across the osteotomy site.
Magnetic Resonance (MR) Compatibility
- Advanced Imaging Safety: MR compatibility ensures that patients requiring postoperative MRI can undergo imaging with minimal artifact and without necessitating plate removal.
- Clinically Versatile: This feature is especially valuable for complex cases that demand ongoing multimodal imaging for diagnosis or follow-up.
Technical Advantages
Enhanced Stability
The rigid fixation achieved through titanium alloy construction and a low-profile locking system improves bone healing and reduces micromotion, crucial factors in preventing non-union or delayed union.
Reduced Postoperative Pain
An anatomically contoured plate can decrease soft tissue irritation, potentially lowering patient discomfort and accelerating recovery timelines.
Surgeon-Controlled Tensioning
The ability to modify or re-tension the locking block screw intraoperatively offers precise control over compression, alignment, and overall surgical outcome.
Versatility in Plate Placement
Multiple plate lengths and shapes (depending on the system’s available catalog) enable surgeons to tailor the fixation construct to specific patient anatomies and surgical approaches.
一般產品規格
規格 | 細節 / 價值 |
產品名稱 | Peta Sternal Closure Plate |
預期用途 | Rigid fixation of the sternum post sternotomy (open-heart surgery, thoracic intervention) |
Plate Material | Titanium alloy (e.g., Ti-6Al-4V ELI) or Stainless Steel (316L), depending on product line |
Plate Thickness | ~1.0–1.5 mm (typical range; verify your actual specs) |
Plate Width | ~10–15 mm (to provide adequate coverage over sternal edges) |
Hole Configuration | Round or oval holes for bone screws, spaced at intervals for adjustable fixation |
Screw Compatibility | Typically 2.4 mm or 2.7 mm diameter cortical bone screws (confirm actual) |
Anatomical Shape | May include slightly contoured or “anatomical” plates for better sternal conformance |
MR 相容性 | MR Conditional or Safe, depending on final metal composition |
無菌 | Sterile (Gamma or EO) |
單次使用 | 是 |
保質期 | ~5 years if packaging remains sealed |
臨床適應症 | Midline sternotomy closure, sternal stability improvement, prevention of dehiscence or infection |
禁忌症 | Grossly insufficient bone stock, active sternal infection (needing further debridement first), etc. |
Peta Sternal Plates
Plate Length (mm) | Hole Count | Thickness (mm) | Plate Shape | 產品編號 | 注意事項 |
40 | 4 | 1.0 | Straight | PETA-40-4-1.0-S | Short plate for partial sternal closure segments |
40 | 4 | 1.2 | Curved | PETA-40-4-1.2-CV | Slight curvature to match upper manubrium |
50 | 5 | 1.0 | Straight | PETA-50-5-1.0-S | Medium length, minimal thickness |
50 | 5 | 1.2 | Slightly contoured | PETA-50-5-1.2-SC | Subtle sternal conformance |
60 | 6 | 1.0 | Straight | PETA-60-6-1.0-S | Extended length for broader sternums |
60 | 6 | 1.2 | Curved | PETA-60-6-1.2-CV | Curved design for mid-lower sternum |
60 | 8 | 1.5 | Straight | PETA-60-8-1.5-S | Additional hole count for robust fixation, thicker plate version |
70 | 6 | 1.0 | Slightly contoured | PETA-70-6-1.0-SC | Longer coverage, minimal thickness |
70 | 8 | 1.2 | Curved | PETA-70-8-1.2-CV | More hole options for multi-screw stability, moderate thickness |
80 | 8 | 1.2 | Straight | PETA-80-8-1.2-S | Extended length for full sternum coverage |
80 | 10 | 1.5 | Slightly contoured | PETA-80-10-1.5-SC | Thicker plate, extended length, multiple hole fixations |
90 | 10 | 1.2 | Curved | PETA-90-10-1.2-CV | Very long plate for entire sternotomy line in certain surgeries |
90 | 12 | 1.5 | Straight | PETA-90-12-1.5-S | Maximum hole count for comprehensive fixation, thicker plate |
相關商品
-
TemREN 外周粥樣斑塊切除系統
查看內容A 旋轉 或 方向性 專門用於 斑塊切除 在外周動脈中,可增加 流明 恢復,同時將氣壓創傷降至最低。
-
InWIRE PTCA 導線
查看內容A range of high-performance coronary guidewires offering 耐用 nitinol or stainless cores, hydrophilic coatings, and multiple tip shapes for crossing 鈣化 或 複雜 coronary lesions.
-
Dolphin PRO Low Profile Crossing Support Catheter
查看內容A 低调 crossing catheter with enhanced pushability 和 trackability, designed for 緊 or heavily 鈣化 lesions in either coronary or peripheral arteries.
-
Atlas 血管內外周支架移植物
查看內容A 有蓋外周支架 供皮 (经过努力)获得 動脈瘤或閉塞性病變的閉塞情況 髂 或 股骨 節段,降低破裂或再次閉塞的風險。