Extender Drug Eluting PTA Balloon Catheter
Extender Drug Eluting PTA Balloon Catheter; A drug-coated balloon for peripheral transluminal angioplasty (PTA), releasing antiproliferative agents to mitigate restenosis in femoral or popliteal arteries.

Elevating Angioplasty with Precision and Efficacy
- Balloon Material: Durable and flexible for precise navigation and deployment.
- Compatibility: Usable with standard catheter systems.
- Size Range: Available in various sizes to accommodate different vascular diameters.
- Compatibility: Usable with standard catheter systems.
Choose for Optimal Drug Delivery
- Deployment: Rapid and controlled balloon inflation and deflation.
- Drug Type: Paclitaxel Incorporates anti-proliferative drugs to prevent restenosis.
- Drug Coating: Homogeneous drug distribution for consistent delivery.
- Drug Type: Paclitaxel Incorporates anti-proliferative drugs to prevent restenosis.


Innovation Meets Vascular Treatment
- Highly compliant balloon material ensures optimal contact with the vessel wall foreffective drug delivery.Therapeutic window achieved after 30 seconds inflation time.Rapid drug release and absorption kinetics ensure targeted therapeutic effects,assuring physicians of sustained results.
Safety and Effectiveness of the Novel TemREN Atherectomy System Combined Use With Extender Drug-Eluting Balloon in Lower Extremity Arteries
Results
For the primary analysis, the rate of lesion technical success was 97.0%, meeting the prospectively established target performance goal of 86%. After postatherectomy adjunctive therapy, residual stenosis was 30% for 100% of lesions means final diameter stenosis, 10.9%.
Early and midterm results of the retrograde transpopliteal approach as the first-line treatment for total occlusions of iliofemoral arteries.
Results
Technical success, defined as restored patency with no stenosis greater than 30%, was achieved in (92.9%) of patients. A patient who was a heavy smoker showed acute symptoms of claudication due to 80% stenosis of the iliac stent 20 days after discharge and was treated with balloon angioplasty.
- 3.0-3.5ug / mm2 drug dosage
- <2mm particles
- Contrast media as a drug carrier
- Minimum drug release during delivery
- Available in Non-Compliant version
- <90% drug transfer to the target lession
- Quick deflation time
- Excellent pushability
一般產品規格
規格 細節 / 價值 產品名稱 Extender Drug PTA Balloon Catheter (Paclitaxel- or Sirolimus-coated, depending on your actual platform) 預期用途 Percutaneous transluminal angioplasty (PTA) in peripheral arteries (e.g., femoral, popliteal, tibial) to reduce restenosis Balloon Material Semi-/Non-Compliant polymer (Nylon, Pebax) with drug coating Drug Coating Paclitaxel or alternative antiproliferative agent (x µg/mm²) Nominal Inflation Pressure ~6–10 atm (depends on diameter) Rated Burst Pressure (RBP) ~12–16 atm (depending on balloon size) Catheter Shaft Length Typically 80–150 cm (adjust for your product line) 導線相容性 0.018” or 0.035” (commonly for peripheral balloons—verify actual design) Coating Release Rapid drug release upon inflation (~30–60 seconds recommended inflation time) 無菌 無菌(環氧乙烷) 單次使用 是 保質期 2–3 years if stored at 15–25 °C in sealed packaging 臨床適應症 PAD (peripheral artery disease), femoropopliteal lesions, below-the-knee disease, in-stent restenosis in peripheral arteries 禁忌症 Highly calcified lesions requiring atherectomy first, allergic reaction to drug coating, severely tortuous or occluded vessels Diameter Range 1.5–6.0 mm (For smaller vessels, BTK or moderate femoral)
Balloon Dia (mm) Balloon Length (mm) Nominal Pressure (atm) RBP (atm) Drug Load (μg) 產品編號 1.5 20 6 12 ~200 EXD-PTA-1.5x20 1.5 40 6 12 ~400 EXD-PTA-1.5x40 2.0 40 7 14 ~600 EXD-PTA-2.0x40 2.0 60 7 14 ~900 EXD-PTA-2.0x60 2.5 80 8 14 ~1200 EXD-PTA-2.5x80 3.0 80 8 14 ~1500 EXD-PTA-3.0x80 3.0 100 8 14 ~1900 EXD-PTA-3.0x100 3.5 100 8 14 ~2200 EXD-PTA-3.5x100 4.0 100 9 16 ~2500 EXD-PTA-4.0x100 4.0 120 9 16 ~3000 EXD-PTA-4.0x120 4.5 120 9 16 ~3400 EXD-PTA-4.5x120 5.0 80 9 16 ~2000 EXD-PTA-5.0x80 5.0 120 9 16 ~3000 EXD-PTA-5.0x120 6.0 80 10 16 ~2200 EXD-PTA-6.0x80 6.0 120 10 16 ~3300 EXD-PTA-6.0x120 Diameter Range 7.0–12.0 mm (For bigger femoral/popliteal or iliac arteries)
Balloon Dia (mm) Balloon Length (mm) Nominal Pressure (atm) RBP (atm) Drug Load (μg) 產品編號 7.0 60 8 14 ~2000 EXD-PTA-7.0x60 7.0 80 8 14 ~2600 EXD-PTA-7.0x80 7.0 120 9 16 ~3900 EXD-PTA-7.0x120 8.0 80 9 16 ~3000 EXD-PTA-8.0x80 8.0 120 9 16 ~4500 EXD-PTA-8.0x120 9.0 80 9 16 ~3400 EXD-PTA-9.0x80 9.0 120 9 16 ~5100 EXD-PTA-9.0x120 10.0 80 10 16 ~3800 EXD-PTA-10.0x80 10.0 120 10 16 ~5700 EXD-PTA-10.0x120 12.0 80 10 16 ~4600 EXD-PTA-12.0x80 12.0 120 10 16 ~6900 EXD-PTA-12.0x120 Paclitaxel-Iopromid Coating- Optimal Drug Delivery: Rapid paclitaxel release into the vessel wall upon balloon inflation aids in inhibiting neointimal hyperplasia.
- Stable Surface Layer: The specialized coating formulation resists delamination, ensuring controlled, uniform distribution of the antiproliferative agent.
Wide Balloon Diameter & Length Range- Diameter: 1.5 mm–12.0 mm covers small distal arteries up to larger peripheral segments.
- Length: 20 mm–220 mm addresses both short, focal lesions and extensive diseased vessel segments—reducing procedural device exchanges.
Low-Profile Catheter & Multiple Guidewire Compatibility- 5F Shaft Design: Minimizes access-site trauma, beneficial for challenging anatomies or smaller access routes.
- Guidewire Options: Accommodates 0.014”, 0.018”, or 0.035” wires, offering flexibility in diverse peripheral vascular lesions.
High Radiopacity for Accurate Placement- Pt-Ir Markers: Ensures clear, real-time balloon positioning under fluoroscopy, facilitating precise lesion coverage and drug deposition.
Varied Catheter Lengths- 80, 90, 120, 135, 150 cm: Multiple workable lengths allow operators to select the ideal configuration for femoral, popliteal, tibial, or other target vessels.
相關商品
-
InWIRE Peripheral Guidewires
查看內容Multiple 外周 wire configurations (hydrophilic, stiff, exchange-length) facilitating safe crossing of complex or calcified lesions and ensuring stable device support.
-
Atlas 外周支架系統
查看內容A 強大 周邊支架 平台,專為 股骨, 髂或 膕窝 病變,確保 充足 徑向支撐和 低 在 PAD 干預中的再狭窄率。
-
Atlas 血管內外周支架移植物
查看內容A 有蓋外周支架 供皮 (经过努力)获得 動脈瘤或閉塞性病變的閉塞情況 髂 或 股骨 節段,降低破裂或再次閉塞的風險。
-
AngioGraphic Manifold
查看內容A 旋轉 或 方向性 專門用於 斑塊切除 在外周動脈中,可增加 流明 恢復,同時將氣壓創傷降至最低。
















































































聯絡與支援
我們能幫上什麼忙?
在我們開始之前,什麼最能形容您?
聯絡與支援
醫療照護專業人員
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
產品查詢
臨床與研究支援
訓練與教育
技術支援
聯絡與支援
病人與照護者
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
產品使用與安全
訂購與付款
支援與後續照護
聯絡與支援
供應商及經銷商
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
合作夥伴與合約
物流與航運
合規性與文件
聯絡與支援
供應商及經銷商
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
新聞稿與新聞
訪談與聲明
活動與會議
聯絡與支援
其他 / 一般諮詢
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
一般資訊
反饋與建議
HeadQuarter 支援專線
- One World Trade Center, 285 Fulton Street.New York, NY 10007, USA
- globalsales@invamed.com
- +1 (347) 535-0630