Atlas venoz stent
Tomirlarning o'tkazuvchanligini saqlash, qon oqimini yaxshilash va surunkali venoz etishmovchilik belgilarini yumshatish orqali venoz obstruktsiyalarni davolash uchun mo'ljallangan, biomos keluvchi metall qotishmalaridan tayyorlangan maxsus implant tizimi.
The Atlas™ Venous Stent, introduced by Bosqinga uchragan—a global medical device manufacturer—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a o'z-o'zidan kengayish nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting bardoshli patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Qo'llash mumkin bo'lmagan holatlar
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Spetsifikatsiya | Tafsilot / qiymat |
Mahsulot nomi | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Joylashtirish mexanizmi | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Radial kuch | Moderate to high, designed to resist extrinsic compression |
Stent diametri diapazoni | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
Radiopak belgilari | Proximal and distal markers for fluoroscopic visualization |
Sterillik | Sterile, single use |
Yaroqlilik muddati | ~3–5 years if stored at 15–25 °C |
Klinik ko'rsatmalar | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Mahsulot kodi | Eslatmalar |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
O' turdagi mahsulotlar
-
Mantis XP Thrombectomy System for Fistula
BatafsilA high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
-
NeuroFill
BatafsilAVMlar, anevrizmalar va neyrovaskulyar anomaliyalar uchun nozik suyuqlik emboliyasi.
-
Viper ULTRA Thrombolysis Catheter
BatafsilAn ultra infusion catheter specialized for direct thrombolytic delivery, featuring multi-hole design to uniformly distribute drugs across large clot segments.
-
Viper™ Valved Infusion Catheters
BatafsilThe Viper™ Valved Infusion Catheter a single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with yoki without a guidewire in place.