Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
A mzunguko system featuring a leaf tip design for mechanical clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
The Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
Vipimo vya Bidhaa
Vipimo | Maelezo / Thamani |
Jina la Bidhaa | Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration |
Matumizi yaliyokusudiwa | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
Ubunifu wa Catheter | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
Nyenzo | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
Urefu wa Kufanya Kazi | ~80–120 cm (varies by product code) |
Mionzi ya mionzi | Distal marker near leaf tip for precise positioning under fluoroscopy |
Kuzaa | Tasa, Matumizi Moja |
Maisha ya Rafu | ~2–3 years at 15–25 °C |
Dalili za Kliniki | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
Contraindications | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
Matrix ya Kuagiza & Ukubwa
Kipenyo cha Nje (F) | Urefu wa Kufanya kazi (cm) | Leaf Tip Diameter (mm) | Kanuni ya Bidhaa | Vidokezo |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
Bidhaa zinazohusiana
-
Inca Trellis Thrombolysis System
Soma zaidiA catheter delivering thrombolytic agents while filter protection prevents distal embolization, ensuring safer pharmacologic dissolution of clots.
-
Extender Dawa Eluting PTCA Puto Catheter Paclitaxel
Soma zaidiA paclitaxel-coated katheta ya puto ya moyo inayolenga kupunguza restenosis wakati wa percutaneous transluminal coronary angioplasty (PTCA), kuhakikisha utoaji wa madawa ya kulevya kwa ukuta wa chombo.
-
AngioCATH Catheter Elekezi
Soma zaidiKatheta zinazoongoza za utendaji wa juu zenye torque mojawapo majibu na ncha sahihi maumbo kwa moyo au pembeni uingiliaji kati, kuhakikisha uwasilishaji thabiti wa kifaa na uwazi wa picha.
-
Teknolojia ya VascuVac Ai ya Utupu Inayosaidiwa
Soma zaidiMfumo wa kibunifu unaotumia teknolojia inayosaidiwa na AI kwa thrombectomy ya utupu yenye ufanisi, iliyoundwa haraka kuondoa thrombi kutoka kwa mishipa ya damu, kurejesha mtiririko wa damu, na kupunguza hatari za kiutaratibu katika uingiliaji wa mishipa.