Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
An over-the-wire (OTW) device merging mzunguko disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFE Inner bitana
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Vipimo vya Bidhaa
Vipimo | Maelezo / Thamani |
Jina la Bidhaa | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Matumizi yaliyokusudiwa | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Ubunifu wa Catheter | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Kipenyo cha Nje (F) | ~5–7F, depending on model |
Urefu wa Kufanya Kazi | ~80–120 cm (varies by product code) |
Utangamano wa Mwongozo | Typically 0.035” (OTW approach) |
Kuzaa | Tasa, Matumizi Moja |
Maisha ya Rafu | ~miaka 2–3 kwa 15–25 °C katika kifungashio kilichofungwa |
Dalili za Kliniki | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Contraindications | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Matrix ya Kuagiza & Ukubwa
Kipenyo cha Nje (F) | Urefu wa Kufanya kazi (cm) | Curve Tip Configuration | Kanuni ya Bidhaa | Vidokezo |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Bidhaa zinazohusiana
-
Viper ULTRA Thrombolysis Catheter
Soma zaidiAn zaidi infusion catheter maalumu kwa moja kwa moja utoaji wa thrombolytic, akishirikiana mashimo mengi muundo wa kusambaza dawa kwa usawa katika sehemu kubwa za damu.
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Soma zaidiA mzunguko system featuring a leaf tip design for mitambo clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
ICT Internal Compression Threrapy
Soma zaidiICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
-
Viper™ Katheta za Uingizaji wa Valve
Soma zaidiThe Viper™ Catheter ya Uingizaji wa Valivu ni a moja-lumen, ncha ya valved mfumo wa utoaji ambao hutoa kubadilika kwa kupenyeza mawakala wa kupambana na thrombus, tofauti ya radiopaque, au ufumbuzi mwingine wa pharmacologic ulioainishwa na daktari na au bila waya wa mwongozo mahali.