DolphinPro Support Catheter
A crossing support catheter for changamano peripheral or coronary lesions, featuring a reinforced shaft na haidrofili coating to ease device delivery.
DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.
Stainless Steel Double-Braiding
A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.
Optimal Push Transition
Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.
Small Crossing Profile
Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.
Telescope Technique
DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.
Broad Clinical Utility
Ideal for femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.
Contraindications
- Extreme vessel tortuosity or diameter below specification
- Active infection or severe vessel dissection precluding wire-based recanalization
- Patient conditions contraindicating endovascular procedures
Technical Specifications
| Vipimo | Maelezo / Thamani |
| Jina la Bidhaa | DolphinPro Support Catheter |
| Matumizi yaliyokusudiwa | Lesion crossing and support in femoro-popliteal & BTK interventions |
| Shaft Construction | Stainless Steel Double-Braiding with advanced polymer coatings |
| Proximal Diameter | Low-profile crossing design; verify available French sizes based on region |
| Distal Tip Profile | Tapered, reinforced tip for improved guidewire entry and lesion crossing |
| Length Options | Common lengths ranging from 65 cm to 150 cm; additional lengths upon request |
| Utangamano wa Mwongozo | Typically 0.014” or 0.018” (verify exact compatibility) |
| Mionzi ya mionzi | Radiopaque distal tip and markers for precise visualization |
| Kuzaa | Provided sterile (single use) |
| Dalili za Kliniki | Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature |
Size & Ordering Matrix
| Ukubwa wa Kifaransa | Usable Length (cm) | Guidewire | Tip Shape | Kanuni ya Bidhaa | Vidokezo |
| 2.4 – 2.6 | 65 / 90 / 135 | 0.014" | Straight, Tapered | DPH-2.6-XX-014 | Suited for BTK interventions requiring flexible distal tip and stable proximal support |
| 2.4 – 2.6 | 100 / 150 | 0.014" | Straight, Tapered | DPH-2.6-XX-014 | Extended length for deeper lesions in SFA or popliteal region |
| 3.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 4.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 5.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 6.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 7.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
Bidhaa zinazohusiana
-

Kiingizaji cha Invaducer
Soma zaidiA titani au aloi mfumo wa sahani ya nje kutoa imara urekebishaji sternotomy ya baada ya katikati, kuimarisha utulivu wa kudumu na kupunguza hatari za maambukizo au uharibifu baada ya upasuaji wa moyo.
-

Nexus Mshipa na Mshipa wa Mshipa
Soma zaidiMadhumuni mengi vena na ateri cannulae kusaidia mzunguko wa extracorporeal wakati wa bypass cardiopulmonary au ECMO, kuhakikisha mojawapo viwango vya mtiririko na utangamano wa damu.
-

Kidhibiti cha Mtiririko wa Tabaka Nyingi cha Stena kwa Upande wa Pembeni
Soma zaidiMtiririko-kuelekeza stent kwa pembeni mishipa, kusambaza tena laminar kutiririka kutoka kwa sehemu za mishipa ya ugonjwa, kusaidia aneurysm au uhifadhi wa tawi la upande.
-

Viper ULTRA Thrombolysis Catheter
Soma zaidiAn zaidi infusion catheter maalumu kwa moja kwa moja utoaji wa thrombolytic, akishirikiana mashimo mengi muundo wa kusambaza dawa kwa usawa katika sehemu kubwa za damu.