Delta Mfumo wa Kupunguza Figo

A masafa ya redio-msingi wa mfumo wa catheter maalumu kwa huruma ya figo upungufu katika shinikizo la damu sugu, kupunguza shughuli za neva ili kudhibiti shinikizo la damu.

Delta Catheter: Pioneering Precision in Renal Denervation

  • Helical Design: The Delta Renal Denervation Catheter sets itself apart through its innovative design and superior performance. 
  • Multi-Electrode: Tailored for the treatment of resistant hypertension, the catheter provides a precise and effective solution, ensuring that patients receive the best possible care.

Redefine Hypertension Treatment
with Delta Renal Denervation

  • The Delta Catheter’s advanced design and tip technology facilitates targeted denervation, resulting in more efficient procedures and enhanced treatment outcomes.
  • With its innovative tip technology, the Delta Catheter guarantees efficient energy delivery and procedural success, paving the way for improved patient outcomes. 

RENAL

ARTERY

ABLATION

SYSTEM

Secure, Swift and Precise:
The Delta Difference in Renal Denervation

With its compatibility with standard systems and equipment, the Delta Catheter is both practical and easy to integrate into existing workflows.

  • Material: Crafted from a state-of-the-art biocompatible ePTFE and a high-strength CoCr, ensuring longevity and stability.
  • Diameter: Ranging from 2.8 mm to 4.8 mm, providing options for various patient needs.
  • Length: Available from 18 mm to 29 mm, accommodating different arterial sizes.
  • Cell Design: Innovatively engineered cell structure delivers exceptional radial strength and flexibility, ensuring the stent conforms securely to the arterial wall.
  • Delivery System: Advanced delivery mechanism ensures precise deployment, easy navigation, and reduced procedure time, enhancing overall surgical efficiency.

A UNIQUE

MULTI-HELİCAL
ABLATION SYSTEM

FITS ALL

ELIGIBLE ANATOMY

6 F Guide Catheter Compatibility
  • Streamlined Interventional Workflow: The Delta Modulator catheter is designed to pass seamlessly through a 6 F guide catheter, reducing procedure complexity.
  • Familiar Access Approach: Maintains alignment with standard femoral arterial entry, minimizing additional training or specialized equipment.
  • 1.5 mm Electrodes: Four distinct radio-opaque electrodes enable circumferential energy delivery, maximizing nerve disruption in fewer lesions.
  • Optimized Positioning: A treatment length of 17–21 mm ensures overlapping energy zones if all electrodes are activated, catering to variable vessel lengths.
  • Real-Time Temperature Monitoring: Provides continuous feedback for energy modulation, improving ablation efficacy while kupunguza thermal injury risks.
  • Precision Control: The thermocouple’s platinum/iridium alloy ensures rapid temperature detection, promoting safe lesion formation.
  • Durable Shaft Support: The robust, molded sleeve maintains catheter integrity, resisting kinks and protecting internal components during complex manipulations.
  • Ergonomic Maneuverability: Smooth transitions between sleeve segments facilitate stable positioning in the renal artery.
  • Tip Marker at 1 mm Proximal of Distal Tip: Guides real-time fluoroscopic alignment.
  • Femoral Shaft Marker at 55 cm: Assists in precise catheter advancement from the femoral access point to the renal artery ostium.
  • 3–8 mm Target: Designed to accommodate typical renal artery dimensions, ensuring broad patient candidacy for renal denervation therapy.
  • Streamlined Interventional Workflow: The Delta Modulator catheter is designed to pass seamlessly through a 6 F guide catheter, reducing procedure complexity.
  • Familiar Access Approach: Maintains alignment with standard femoral arterial entry, minimizing additional training or specialized equipment.
  • 1.5 mm Electrodes: Four distinct radio-opaque electrodes enable circumferential energy delivery, maximizing nerve disruption in fewer lesions.
  • Optimized Positioning: A treatment length of 17–21 mm ensures overlapping energy zones if all electrodes are activated, catering to variable vessel lengths.
  • Real-Time Temperature Monitoring: Provides continuous feedback for energy modulation, improving ablation efficacy while kupunguza thermal injury risks.
  • Precision Control: The thermocouple’s platinum/iridium alloy ensures rapid temperature detection, promoting safe lesion formation.
  • Durable Shaft Support: The robust, molded sleeve maintains catheter integrity, resisting kinks and protecting internal components during complex manipulations.
  • Ergonomic Maneuverability: Smooth transitions between sleeve segments facilitate stable positioning in the renal artery.
  • Tip Marker at 1 mm Proximal of Distal Tip: Guides real-time fluoroscopic alignment.
  • Femoral Shaft Marker at 55 cm: Assists in precise catheter advancement from the femoral access point to the renal artery ostium.
  • 3–8 mm Target: Designed to accommodate typical renal artery dimensions, ensuring broad patient candidacy for renal denervation therapy.

Maelezo ya Jumla ya Bidhaa

Vipimo Maelezo / Thamani
Jina la Bidhaa Delta Mfumo wa Kupunguza Figo
Matumizi yaliyokusudiwa Catheter-based ablation of renal sympathetic nerves to treat resistant hypertension
Ubunifu wa Catheter Multi-electrode or single-electrode RF ablation catheter with integrated temperature sensors
Nyenzo Pebax/Polyamide shaft with braided reinforcement, flexible tip
Catheter Outer Diameter Typically 6F or 7F
Urefu wa Kufanya Kazi ~100–120 cm (depending on model)
Electrode Configuration 4 or 6 RF electrodes radially spaced, or single spiral electrode, plus temperature feedback
RF Energy Range ~5–15 W per electrode (depending on design)
Frequency ~460–500 kHz (common for RF ablation)
Irrigation/Saline Port Optional for cooling, if device design includes fluid infusion
Utangamano wa Mwongozo Typically 0.014” or 0.018” (check specific product line)
Kuzaa Asiyezaa (Ethilini Oksidi)
Matumizi Moja Ndiyo
Maisha ya Rafu Miaka 2-3 ikiwa imehifadhiwa bila kufunguliwa kwa 15-25 °C
Joto la Uendeshaji 15–25 °C recommended for storage
Dalili za Kliniki Resistant arterial hypertension where lifestyle and medications fail, enabling reduction of sympathetic tone
Contraindications Severe renal artery stenosis, multiple renal arteries unfit for ablation, or known intolerance to device materials

6F Renal Denervation Catheters

Ukubwa wa Kifaransa Urefu wa Kufanya kazi (cm) Electrode Setup Guidewire Kanuni ya Bidhaa Vidokezo
6F 100 4-electrode array 0.014” DLT-6F-100-4A Standard length, radial 4-electrode configuration
6F 100 Single spiral electrode 0.014” DLT-6F-100-SSP Spiral coil design for circumferential ablation
6F 110 4-electrode array 0.014” DLT-6F-110-4A Extended length for deeper renal artery access
6F 110 6-electrode array 0.014” DLT-6F-110-6A More contact points for multi-spot ablation

7F Renal Denervation Catheters

Ukubwa wa Kifaransa Urefu wa Kufanya kazi (cm) Electrode Setup Guidewire Kanuni ya Bidhaa Vidokezo
7F 100 4-electrode array 0.014” or 0.018” DLT-7F-100-4A Larger OD allows thicker integrated sensors or irrigation
7F 100 6-electrode array 0.014” or 0.018” DLT-7F-100-6A Enhanced radial coverage in a single ablation pass
7F 110 Single spiral electrode 0.014” or 0.018” DLT-7F-110-SSP Extended length with spiral design for wide segments
7F 120 6-electrode array + Irrig. 0.014” or 0.018” DLT-7F-120-6Ai Optional irrigation port for cooling during ablation

8F

Ukubwa wa Kifaransa Urefu wa Kufanya kazi (cm) Electrode Setup Guidewire Kanuni ya Bidhaa Vidokezo
8F 100 6-electrode radial array 0.018" DLT-8F-100-6A Higher flow or stiffer design for tough anatomies
8F 110 6-electrode + irrigation 0.018" DLT-8F-110-6Ai Cooling feature plus multiple electrodes for thorough ablation
8F 120 Double spiral coil (rare) 0.018" DLT-8F-120-DSC If your line includes unique double spiral layout (example)