MultiBEAM Filter för Vena Cava Inferior (IVC)
En konvertibel eller återvinningsbar IVC-filter förhindrar Lungemboli genom att fånga upp blodproppar som färdas genom vena cava inferior, vilket garanterar säkerheten för högriskpatienter.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
Kontraindikationer
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
Produktspecifikationer
Specifikation | Detalj / värde |
Produktens namn | MultiBEAM Filter för Vena Cava Inferior (IVC) |
Avsedd användning | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
Mekanism för utplacering | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
Radiopaka markörer | Distal apex or anchor tips for fluoroscopic identification |
MR-kompatibilitet | MR Conditional (verify labeling) |
Sterilitet | Steril, engångsbruk |
Hållbarhet | ~3–5 years if stored at 15–25 °C in sealed packaging |
Kliniska indikationer | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
Kontraindikationer | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
Beställning & storleksmatris
IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | Produktkod | Anteckningar |
< 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
< 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
Relaterade produkter
-
VeinOFF Medel för behandling av åderbråck
Läs merEn specialiserad Skleroseringsmedel eller självhäftande formel som syftar till icke-termisk borttagning av åderbråck, vilket kräver minimal anestesi och kort behandlingstid.
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Läs merA roterande system featuring a leaf tip design for mekanisk clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
ICT Intern kompressionsterapi
Läs merICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
-
Mantis XP Thrombectomy System for Fistula
Läs merA high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.