Atlas Koronarstentsystem rostfritt stål
A rostfritt stål erbjudande inom kranskärlsstent robust strukturell integritet och lätt för rutinmässiga perkutana kranskärlsingrepp (PCI), med balans mellan kostnadseffektivitet och tillförlitlig prestanda.
Den ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Allmänna produktspecifikationer
Specifikation | Detalj / värde |
Produktens namn | Atlas Coronary Stent (Stainless Steel) |
Stent Type | Balloon-Expandable Coronary Stent |
Material | 316L Stainless Steel (Medical Grade) |
Strut Thickness | ~100 μm (typical) |
Design | Open-Cell or Hybrid-Cell design (varies by specific model) |
Nominal Pressure (NP) | ~8–9 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Leveranssystem | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Kompatibilitet med guidewire | 0.014” |
Indikationer | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
Kontraindikationer | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
Sterilitet | Steril (etylenoxid) |
Engångsbruk | Ja |
Hållbarhet | 2–3 years (based on final packaging and coating, if any) |
Driftstemperatur | Recommended 15–25 °C for storage |
Detaljerade storleksbaserade beställnings- och produktkoder
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Produktkod |
2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Relaterade produkter
-
Hero LASER-system för borttagning av bly
Läs merA laserbaserad Extraktionsanordning som möjliggör exakt och säker borttagning av hjärtavledningar (pacemaker eller ICD) vid infektion, fel på avledningen eller uppgraderingar.
-
GuideX Extension Catheter
Läs merEn extension or “mother-and-child” catheter offering enhanced support och reach within tortuous or distal coronary/peripheral segments, enabling stable device navigation.
-
Extender Drug Eluting PTCA-ballongkateter Paclitaxel
Läs merA paklitaxel-belagd ballongkateter för kranskärl som är inriktad på minska restenos under perkutan transluminal koronar angioplastik (PTCA), vilket säkerställer effektiv läkemedelstillförsel till kärlväggen.
-
AngioTEN Förslutningsenhet
Läs merA perkutan vaskulärt förslutningssystem för arteriell eller venös åtkomst till webbplatser, vilket möjliggör säker hemostas efter kateterisering eller interventionella ingrepp.