JaGuar Geleidingsmantel
A gevlochten geleidende mantel die koppel controle en kink weerstand voor veilige apparaatnavigatie in perifeer of visceraal interventies.
De Jaguar® Braided Long Sheath is een multipurpose catheter system designed to function both as a guiding catheter and an introducer sheath—streamlining vascular access in diagnostic en interventional procedures. Constructed with coil reinforcement, a radiopaque marker, and a hydrophilic distal tip coating, the Jaguar® Sheath facilitates smooth advancement, nauwkeurig positioning, and robust device compatibility in peripheral, renal, and carotid arteries.
Coil-Reinforced Shaft
- Stainless Steel Coil: Embedded within the sheath walls, this coil provides structural integrity en resistance to kinking—even under challenging anatomical angles.
- Stable Navigation: Enhances pushability and torque control, ensuring betrouwbare catheter placement through tortuous vasculature.
Radiopaque Marker
- 5 mm from Distal Tip: A coil-based radiopaque segment ensures clear fluoroscopic visibility, facilitating precise sheath positioning at the target vessel site.
- Enhanced Procedural Accuracy: Real-time feedback under X-ray imaging minimizes guesswork and potentially shortens fluoroscopy times.
Hydrofiele distale coating
- Smooth Entry & Tracking: The distal 5 cm portion is coated with a low-friction hydrophilic layer, reducing vessel wall friction and safeguarding intimal surfaces.
- Easier Crossing of Lesions: Helps mitigate navigation resistance in tight or calcified segments—especially beneficial in lower extremity or renal arteries.
PTFE Inner Liner
- Lumen met lage wrijving: Polytetrafluoroethylene (PTFE) lining decreases internal drag, ensuring efficient passage of devices (e.g., guidewires, balloons, stents).
- Reduced Catheter “Kick-Back”: Improves device stability, mitigating back-and-forth movements during manipulations.
High Guidewire Compatibility
- Maximum Diameter 0.038” (0.97 mm): Accommodates diverse endovascular devices and ensures synergy with standard or large-caliber guidewires commonly used in peripheral, renal, and carotid interventions.
PE/PEBAX Outer Structure
- Proximal Rigidity & Distal Flexibility: The sheath shaft’s polymer blend balances stable push performance with a flexible distal region, promoting safe passage through curved vessels.
Configurable Hemostatic Valve & Dilator
- Complete Packaging: Delivers a choice of hemostasis valve styles and a matched dilator, enabling quick setup and effective fluid containment.
- Optimized Vessel Access: Minimizes blood loss, secures attachments, and reduces contamination risk.
- Stainless Steel Coil: Embedded within the sheath walls, this coil provides structural integrity en resistance to kinking—even under challenging anatomical angles.
- Stable Navigation: Enhances pushability and torque control, ensuring betrouwbare catheter placement through tortuous vasculature.
- 5 mm from Distal Tip: A coil-based radiopaque segment ensures clear fluoroscopic visibility, facilitating precise sheath positioning at the target vessel site.
- Enhanced Procedural Accuracy: Real-time feedback under X-ray imaging minimizes guesswork and potentially shortens fluoroscopy times.
- Smooth Entry & Tracking: The distal 5 cm portion is coated with a low-friction hydrophilic layer, reducing vessel wall friction and safeguarding intimal surfaces.
- Easier Crossing of Lesions: Helps mitigate navigation resistance in tight or calcified segments—especially beneficial in lower extremity or renal arteries.
- Lumen met lage wrijving: Polytetrafluoroethylene (PTFE) lining decreases internal drag, ensuring efficient passage of devices (e.g., guidewires, balloons, stents).
- Reduced Catheter “Kick-Back”: Improves device stability, mitigating back-and-forth movements during manipulations.
- Maximum Diameter 0.038” (0.97 mm): Accommodates diverse endovascular devices and ensures synergy with standard or large-caliber guidewires commonly used in peripheral, renal, and carotid interventions.
- Proximal Rigidity & Distal Flexibility: The sheath shaft’s polymer blend balances stable push performance with a flexible distal region, promoting safe passage through curved vessels.
- Complete Packaging: Delivers a choice of hemostasis valve styles and a matched dilator, enabling quick setup and effective fluid containment.
- Optimized Vessel Access: Minimizes blood loss, secures attachments, and reduces contamination risk.
Algemene productspecificaties
Specificatie | Detail / Waarde |
Productnaam | JaGuar Geleidingsmantel |
Beoogd gebruik | Provides stable, kink-resistant access for interventional devices in peripheral or coronary procedures |
Sheath Material | Braided or coiled polymer (e.g., Pebax/Polyamide) with PTFE or hydrophilic liner |
Sheath Sizes | ~5F–9F (depending on your actual product line) |
Working Lengths | Typically 45–90 cm for peripheral approaches; 23–45 cm for coronary (adjust as needed) |
Tip configuratie | Straight, angled, or soft tapered tip |
Hemostatic Valve | Integrated valve with side port for flushing/infusion |
Radiopaque Marker | Distal marker band for positioning under fluoroscopy |
Steriliteit | Steriel (ethyleenoxide) |
Eenmalig gebruik | Ja |
Houdbaarheid | ~2–3 years if sealed and stored at 15–25 °C |
Bedrijfstemperatuur | 15-25 °C aanbevolen opslag |
Klinische indicaties | Femoral or radial artery access for coronary/peripheral interventions, sheath over guidewire approach |
Contra-indicaties | Vessels too small or diseased to accommodate the chosen French size, significant vessel tortuosity, known device material allergy |
5F Range
F Size | Sheath Length (cm) | Tip Style | Productcode | Opmerkingen |
5F | 23 | Straight | JGR-5F-23-ST | Short coronary approach; standard tip |
5F | 45 | Tapered | JGR-5F-45-TP | Longer length, tapered for radial or brachial access |
6F Range
F Size | Sheath Length (cm) | Tip Style | Productcode | Opmerkingen |
6F | 23 | Straight | JGR-6F-23-ST | Common short sheath for coronary interventions |
6F | 23 | Angled | JGR-6F-23-AN | Slight angle for vessel alignment |
6F | 45 | Straight | JGR-6F-45-ST | Longer approach for femoral or radial usage |
6F | 45 | Tapered | JGR-6F-45-TP | Minimizes trauma on insertion |
7F Range
F Size | Sheath Length (cm) | Tip Style | Productcode | Opmerkingen |
7F | 23 | Straight | JGR-7F-23-ST | Larger lumen for advanced device usage |
7F | 45 | Tapered | JGR-7F-45-TP | Balanced approach for femoral/peripheral interventions |
7F | 60 | Straight | JGR-7F-60-ST | Extended length for deeper vessel cannulation |
8F Range
F Size | Sheath Length (cm) | Tip Style | Productcode | Opmerkingen |
8F | 45 | Straight | JGR-8F-45-ST | Large bore for complex device deployment |
8F | 60 | Angled | JGR-8F-60-AN | For angled approach in iliac or SFA interventions |
8F | 70 | Tapered | JGR-8F-70-TP | Longest approach, soft tip |
9F Range
F Size | Sheath Length (cm) | Tip Style | Productcode | Opmerkingen |
9F | 45 | Straight | JGR-9F-45-ST | Extra-large lumen for big catheters or devices |
9F | 60 | Tapered | JGR-9F-60-TP | Reduces insertion trauma, extended length |
9F | 70 | Angled | JGR-9F-70-AN | Angled tip for specialized vascular anatomies |