Horus Fiber Optic 300/500/600 Laser Probes
A titanium of legering sternale plaat systeem dat stijf fixatie na middellijn sternotomie, verbetering van sternale stabiliteit en het verminderen van het risico op infectie of dehiscentie na hartchirurgie.
Horus Fiber Optic 300/500/600 Laser Probes by Invamed are designed to deliver precise and efficient laser photocoagulation treatments within the vitreous cavity, targeting wavelengths from 500 nm to 900 nm. Each probe utilizes fused-tip laser fibers that minimize ghosting and enable the surgeon to work closer to the retinal tissue, enhancing accuracy in delicate surgical scenarios such as retinal tears, diabetic retinopathy, or macular edema.
Fused Fiber Tip
Laser fibers are fused at the tip, reducing internal reflections or “ghosting” that can compromise beam quality. This design ensures high-quality energy transmission and the ability to operate very close to the retina without dispersing or scattering the laser.
High-Purity Fiber Construction
Utilizing medical-grade silica fibers, Horus Laser Probes support consistent photocoagulation performance across 500–900 nm wavelengths, addressing a range of retinal pathologies.
Minimally Invasive Shaft
The low-profile, flexible probe shaft allows smooth insertion through small-gauge cannulas (e.g., 23G, 25G, 27G), preserving ocular structures and reducing surgical trauma.
Compatible with Major Laser Platforms
Adaptable to common ophthalmic laser systems (argon, diode, green, red, yellow), meeting the photocoagulation demands in retina clinics and ambulatory surgery centers.
Ergonomic Handle & Orientation
Features an optimized grip for enhanced maneuverability during vitreoretinal surgery, aiding stability and precise targeting of retinal lesions.
Contra-indicaties
- Non-intact globe or patients in whom intraocular laser therapy is contraindicated
- Inadequate visualization of the retina
- Patients with active intraocular infection or uncorrectable coagulopathies
Gerelateerde producten
-
Invaducer Intraducer
Lees meerA titanium of legering sternale plaat systeem dat stijf fixatie na middellijn sternotomie, verbetering van sternale stabiliteit en het verminderen van het risico op infectie of dehiscentie na hartchirurgie.
-
Peta Radiofrequente ablatie (RFA), zenuw
Lees meerA titanium of legering sternale plaat systeem dat stijf fixatie na middellijn sternotomie, verbetering van sternale stabiliteit en het verminderen van het risico op infectie of dehiscentie na hartchirurgie.
-
Horus® Optic Laser Probes (Photocoagulation)
Lees meerA titanium of legering sternale plaat systeem dat stijf fixatie na middellijn sternotomie, verbetering van sternale stabiliteit en het verminderen van het risico op infectie of dehiscentie na hartchirurgie.
-
NeuroFill
Lees meerPrecisievloeistofembolic voor AVM's, aneurysma's en neurovasculaire afwijkingen.