AngioTEN Sluitapparaat
A percutaan vasculair sluitsysteem voor slagader of veneus toegangssites, waardoor beveilig hemostase na katheterisatie of interventionele procedures.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Contra-indicaties
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Productspecificaties
Specificatie | Detail / Waarde |
Productnaam | AngioTEN Sluitapparaat |
Beoogd gebruik | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Steriliteit | Steriel, eenmalig gebruik |
Houdbaarheid | ~2–3 years at 15–25 °C |
Bestel- en formaatmatrix
Access Size (F) | Closure Method | Deployment Steps | Productcode |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Gerelateerde producten
-
Extender Drug Eluting PTA Balloon Catheter
Lees meerExtender Drug Eluting PTA Balloon Catheter; A drug-coated balloon for peripheral transluminal angioplasty (PTA), releasing antiproliferative agents to mitigate restenosis in femoral or popliteal arteries.
-
Atlas Endovascular Peripheral Stent Graft
Lees meerA covered peripheral stent graft offering beveilig occlusion of aneurysms or occlusive lesions in iliac of femoral segments, reducing risk of rupture or re-occlusion.
-
Atlas Coronair Stentsysteem Roestvrij Staal
Lees meerA roestvrij staal aanbod van coronaire stents robuust structurele integriteit en eenvoudig leverbaarheid voor routinematige percutane coronaire interventies (PCI), waarbij kostenefficiëntie wordt afgewogen tegen betrouwbare prestaties.
-
InWIRE 0,014" & 0,018" CTO geleidingsdraad
Lees meerEen reeks van hoogwaardige aanbod van geleidingsdraden duurzaam nitinol of roestvrij kernen, hydrofiele coatings en meerdere tipvormen voor het kruisen van verkalkt of complex coronaire en perifere laesies.