Коронарлық стенттік жүйе кобальтты хромды шығаратын ATLAS препараты
А кобальт-хром коронарлық стентті жеткізу тұрақты радиалды беріктік және тамаша қадағалау мүмкіндігі, үшін қолайлы кешен немесе кальциленген коронарлық зақымданулар, сонымен бірге минималды кері қайтаруды қамтамасыз етеді.
The ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
Техникалық сипаттама | Мәліметтер / Мән |
Өнім атауы | Atlas Coronary Stent (Cobalt Chromium) |
Стент түрі | Balloon-Expandable Coronary Stent |
Материал | Cobalt-Chromium Alloy |
Strut Thickness | ~80 µm (typical) |
Дизайн | Open-cell or hybrid-cell architecture (depending on exact model) |
Nominal Pressure (NP) | 9–10 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Бағыттаушы сымның үйлесімділігі | 0.014” |
Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
Көрсеткіштер | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
Қарсы көрсеткіштер | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
Стерилділік | Стерильді (этилен оксиді) |
Бір реттік пайдалану | Иә |
Жарамдылық мерзімі | 2–3 years (depending on final packaging and polymer, if any) |
Жұмыс температурасы | Recommended 15–25 °C for storage |
Өлшемге негізделген егжей-тегжейлі тапсырыс және өнім кодтары
Stent Diameter (mm) | Стент ұзындығы (мм) | Nominal Pressure (atm) | RBP (atm) | Өнім коды |
2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
Қатысты өнімдер
-
Atlas Коронарлық стент жүйесі баспайтын болаттан
Толығырақ оқыңызА баспайтын болат коронарлық стентті ұсыну берік құрылымдық тұтастық және оңай кәдімгі тері арқылы коронарлық араласуларға (PCI) жеткізу, сенімді өнімділікпен үнемділікті теңестіру.
-
Extender PTCA баллонды катетер
Толығырақ оқыңызА стандартты жоғары қысым коронарлық шар арналған зақымдануға бейімділік немесе дербес ангиопластика, дәл инфляция профильдерін және қысқартылған қиылысу профильдерін ұсынады.
-
Peta төстің жабылатын тақтасы
Толығырақ оқыңызА титан немесе қорытпа кеуде пластинасының жүйесін қамтамасыз етеді қатты бекіту ортаңғы сызықтан кейінгі стернотомия, күшейту төс сүйегінің тұрақтылығы және кардиохирургиялық операциядан кейін инфекция немесе ыдырау қаупін азайту.
-
AngioCATH бағыттаушы катетер
Толығырақ оқыңызЖоғары өнімді бағыттаушы катетерлері бар оңтайлы момент жауап және нақты ұшы үшін пішіндер коронарлық немесе перифериялық құрылғының тұрақты жеткізілімін және кескіннің анықтығын қамтамасыз ететін араласулар.