について Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
製品仕様
仕様 | 詳細 / 価値 |
製品名 | Mantis リーフチップ回転式血栓摘出術および超吸引術 |
使用目的 | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
カテーテルのデザイン | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
素材 | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
カテーテル外径 | ~5–7F, depending on model and tip size |
作業長 | ~80–120 cm (varies by product code) |
ラジオパシティ | Distal marker near leaf tip for precise positioning under fluoroscopy |
不妊症 | 滅菌済み、シングルユース |
賞味期限 | ~2–3 years at 15–25 °C |
臨床適応症 | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
禁忌事項 | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
オーダー&サイズマトリックス
外径(F) | 作業長 (cm) | Leaf Tip Diameter (mm) | 商品コード | 備考 |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
関連商品
-
InWIRE 末梢ガイドワイヤー
続きを読む複数 ペリフェラル ワイヤー構成(親水性、剛性、交換長)により、以下のことが容易になる。 セーフ 複雑な病変や石灰化病変を横断し、安定したデバイス支持を確保する。
-
Extender 薬剤溶出PTCAバルーンカテーテル パクリタキセル
続きを読むA パクリタキセルコート 冠動脈バルーンカテーテル 再狭窄の減少 経皮経管冠動脈形成術(PTCA)の際に、血管壁への効果的な薬物送達を確実にする。
-
ThermoBLOCK 下肢静脈瘤ラジオ波焼灼システム
続きを読むA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
-
AngioCATHガイディング・カテーテル
続きを読む高性能ガイディングカテーテル 最適トルク 反応と 精密チップ 形状 冠状 または ペリフェラル インターベンションを行い、安定したデバイスの送達と画像の鮮明さを確保する。