Mantis CURVEオーバー・ザ・ワイヤー(OTW)回転式薬力学的血栓除去システム
アン オーバーザワイヤー (OTW)デバイスのマージ 回転 とのディスラプション 薬理学的 を溶解し、健康な血管壁を保護しながら大きな血栓を効果的に除去する。
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFEインナーライニング
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
製品仕様
| 仕様 | 詳細 / 価値 |
| 製品名 | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
| 使用目的 | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
| カテーテルのデザイン | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
| Rotational Speed Range | ~40k–80k rpm (verify final) |
| Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
| 外径(F) | ~5–7F, depending on model |
| 作業長 | ~80–120 cm (varies by product code) |
| ガイドワイヤーの適合性 | Typically 0.035” (OTW approach) |
| 不妊症 | 滅菌済み、シングルユース |
| 賞味期限 | ~密封包装で15~25℃にて~2~3年 |
| 臨床適応症 | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
| 禁忌事項 | Extremely tortuous vessels, heavy calcification, or known device material allergies |
オーダー&サイズマトリックス
| 外径(F) | 作業長 (cm) | Curve Tip Configuration | 商品コード | 備考 |
| 5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
| 5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
| 6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
| 6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
| 7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
| 7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
関連商品
-

InWIRE 末梢ガイドワイヤー
続きを読む複数 ペリフェラル ワイヤー構成(親水性、剛性、交換長)により、以下のことが容易になる。 セーフ 複雑な病変や石灰化病変を横断し、安定したデバイス支持を確保する。
-

Mantis PRO 回転血栓除去術と超吸引術
続きを読むA 回転 システム 機械的 血液凝固プラス 強い 深部静脈または動脈閉塞における吸引能力。
-

VascuVac Aiアシスト真空血栓除去技術
続きを読む効率的な真空血栓除去のためにAI支援技術を活用した革新的なシステムで、以下のように設計されている。 迅速な血栓除去 血管から、 血流を回復させる、 そして 手続き上のリスクを最小限に抑える 血管インターベンションにおける
-

AngioCATHガイディング・カテーテル
続きを読む高性能ガイディングカテーテル 最適トルク 反応と 精密チップ 形状 冠状 または ペリフェラル インターベンションを行い、安定したデバイスの送達と画像の鮮明さを確保する。