ICT内部圧縮スレーパー
ICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
Unlike standard therapies for superficial venous insufficiency—which often eliminate or destroy the problematic vein (via heat ablation, embolization, or surgical stripping)—the ICT Valvular Leak Sealer Reconstruction System by Invamed offers a valve-preserving strategy. Using precise sealing and support around the insufficient venous valve segment, this minimally invasive device supports restoration of natural blood flow dynamics, striving to eliminate reflux while retaining vessel integrity.
Reconstructive Venous Valve Treatment
- Targets incompetent valves in the superficial vein (commonly the great or small saphenous veins), sealing the leaky valve leaflets instead of ablating or removing the vein.
- Helps maintain normal venous return and overall vein physiology, reducing risk of collateral vein overload or new varicosities.
Minimally Invasive Sealing Mechanism
- Employs an implant or sealing device designed to reposition and reinforce the valve cusps, closing the regurgitant gap.
- Can be introduced via a percutaneous approach, guided by ultrasound or endovenous imaging—limiting dissection and promoting rapid recovery.
Preserves Vein Function
- By not destroying or removing the saphenous segment, the system maintains potential future access for coronary or peripheral bypass grafting.
- Encourages physiological drainage in the treated limb, diminishing post-procedure edema, discomfort, or long-term complication rates associated with vessel loss.
Durable Biocompatible Materials
- Constructed from medical-grade alloys or polymer composites that resist fatigue under repeated venous pressure cycles.
- Low-profile design seeks to minimize localized thrombogenic risk and adapt to variations in valve morphology.
臨床適応症
- Indicated for;
Deep Venous Insufficiency (DVI) • Superficial Venous Insufficiency (SVI)
ICT is an implant device in which a gel implant consisting of a mixture of hyaluronic acid and n-butyl-cyanoacrylate (n-BCA) is placed around the periphery of the incompetent deep venous valve or terminal valve of the saphenofemoral junction (SFJ) and in the fascia layer, rigid support.
関連商品
-
Nexus 静脈・動脈カニューレ
続きを読む多目的 静脈性 そして 動脈 カニューレ 体外循環 心肺バイパス中またはECMO中に、最適な状態を確保する。 流量 そして 血液適合性.
-
MultiBEAM 下大静脈(IVC)フィルター
続きを読むコンバーチブル 回収可能 IVCフィルターによる予防 肺塞栓症 下大静脈を通過する血栓を遮断することで、リスクの高い患者の安全性を確保している。
-
InWIRE 末梢ガイドワイヤー
続きを読む複数 ペリフェラル ワイヤー構成(親水性、剛性、交換長)により、以下のことが容易になる。 セーフ 複雑な病変や石灰化病変を横断し、安定したデバイス支持を確保する。
-
Venablock™静脈瘤治療静脈閉鎖システム
続きを読むVenablock™静脈瘤治療静脈閉鎖システム; A シアノアクリレート系 静脈閉鎖システム 軽薄 静脈不全, 分娩 非熱 最小限の局所麻酔で閉塞し 速い 手術後の回復。