DolphinPro Support Catheter

A crossing support catheter for 複雑 peripheral or coronary lesions, featuring a reinforced shaft そして hydrophilic coating to ease device delivery.

DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.

Stainless Steel Double-Braiding

A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.

Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.

Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.

DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.

Ideal for femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.

  • Extreme vessel tortuosity or diameter below specification
  • Active infection or severe vessel dissection precluding wire-based recanalization
  • Patient conditions contraindicating endovascular procedures

Technical Specifications

仕様 詳細 / 価値
製品名 DolphinPro Support Catheter
使用目的 Lesion crossing and support in femoro-popliteal & BTK interventions
Shaft Construction Stainless Steel Double-Braiding with advanced polymer coatings
Proximal Diameter Low-profile crossing design; verify available French sizes based on region
Distal Tip Profile Tapered, reinforced tip for improved guidewire entry and lesion crossing
Length Options Common lengths ranging from 65 cm to 150 cm; additional lengths upon request
ガイドワイヤーの適合性 Typically 0.014” or 0.018” (verify exact compatibility)
ラジオパシティ Radiopaque distal tip and markers for precise visualization
不妊症 Provided sterile (single use)
臨床適応症 Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature

Size & Ordering Matrix

フランスサイズ Usable Length (cm) Guidewire Tip Shape 商品コード 備考
2.4 – 2.6 65 / 90 / 135 0.014” Straight, Tapered DPH-2.6-XX-014 Suited for BTK interventions requiring flexible distal tip and stable proximal support
2.4 – 2.6 100 / 150 0.014” Straight, Tapered DPH-2.6-XX-014 Extended length for deeper lesions in SFA or popliteal region
3.0 80 / 135 / 150 0.018" Slight Angled (option) DPH-3.0-XX-018 Larger internal diameter for enhanced pushability and crossing in more robust vessel segments
4.0 80 / 135 / 150 0.018" Slight Angled (option) DPH-3.0-XX-018 Larger internal diameter for enhanced pushability and crossing in more robust vessel segments
5.0 80 / 135 / 150 0.018" Slight Angled (option) DPH-3.0-XX-018 Larger internal diameter for enhanced pushability and crossing in more robust vessel segments
6.0 80 / 135 / 150 0.035" Slight Angled (option) DPH-3.0-XX-035 Larger internal diameter for enhanced pushability and crossing in more robust vessel segments
7.0 80 / 135 / 150 0.035" Slight Angled (option) DPH-3.0-XX-035 Larger internal diameter for enhanced pushability and crossing in more robust vessel segments