Atlas Endovascular Peripheral Stent Graft
A covered peripheral stent graft offering セキュア occlusion of aneurysms or occlusive lesions in iliac または femoral segments, reducing risk of rupture or re-occlusion.

Reinforced Stability, Unparalleled Durability
Elevate Vascular Repair with the Power of Carbon:
• Durability: The carbon coating adds an extra layer of strength and resilience. • Biocompatibility: Designed to minimize irritation and promote faster recovery. • Radiopacity: Enhanced visibility under imaging for precise placement.


Precision, Protection, Performance:
SIGNIFICANT ADVANCEMENT IN ENDOVASCULAR REPAIR TECHNOLOGY
ENHANCED WITH A ROBUST CARBON COATING OPTIMIZED FOR BOTH FLEXIBILITY AND CONFORMABILITY
Self-Expanding Nitinol Framework
- Shape-Memory Alloy: Nitinol’s superelastic properties enable consistent radial force to maintain stent apposition, conforming effectively to vessel anatomies.
- Tantalum Markings: Both stent ends include tantalum markers, providing high radiopacity for precise positioning under fluoroscopy.
Microporous ePTFE Graft Material
- Sealing Function: The ePTFE covering excludes blood flow from the aneurysmal or diseased arterial wall, helping reduce the risk of endoleaks.
- Biocompatible & Low Profile: The microporous structure supports healing while limiting inflammatory responses.
Single-Stent Design
- Straightforward Implantation: Simplifies device selection and deployment, particularly beneficial in peripheral lesions requiring a single stent graft solution.
- Enhanced Device Integrity: Minimizes potential junctional leak points or component separations sometimes encountered in multi-piece stent systems.
Carbon Surface Coating
- Thromboresistant: The carbon coating on the stent struts aims to reduce platelet adhesion, promoting stable device integration and lower incidence of thrombosis.
- Smooth Flow Lumen: Enhances hemodynamic compatibility and may further limit intimal hyperplasia.
Wide Diameter and Length Range
- Stent Graft Size: 5.0 to 10.0 mm diameters address multiple peripheral vessel diameters.
- Nominal Stent Graft Length: Ranging from 18 to 58 mm in designated sizes (18, 22, 28, 38, 58 or 18, 23, 27, 37, 57)—covering a broad spectrum of lesion lengths.
一般製品仕様
仕様 | 詳細 / 価値 |
製品名 | Atlas Endovascular Stent Graft |
使用目的 | Endovascular repair of peripheral aneurysms, arterial occlusive disease, or traumatic injuries (iliac, femoral, popliteal) |
Graft Material | ePTFE covering over metal scaffold |
Scaffold Material | Nitinol (self-expanding depending on design) |
Deployment Method | Over-the-wire with introducer sheath (commonly 14F–18F, depending on stent diameter) |
ラジアルフォース | Medium-High, ensuring stable vessel wall apposition |
Delivery Shaft Length | Typically 80–120 cm (verify exact product specs) |
放射線不透過性マーカー | Proximal and distal markers to guide accurate placement |
不妊症 | 無菌(エチレンオキシド) |
シングルユース | はい |
賞味期限 | ~3–5 years if stored at 15–25 °C in sealed packaging |
MRの互換性 | MR Conditional (verify labeling) |
臨床適応症 | Peripheral artery aneurysms (iliac, femoral), endoluminal bridging for traumatic or pseudoaneurysms, possible bypass for occlusive lesions |
禁忌事項 | Extremely calcified or tortuous vessels preventing safe device passage, known nickel or metal allergies |
Atlas Endovascular Stent Graft
直径 (mm) | 長さ (mm) | シース・レック(F) | 商品コード | 備考 |
6 | 40 | ~14F | AESG-6x40 | Small diameter for distal external iliac or femoral |
6 | 60 | ~14F | AESG-6x60 | |
6 | 80 | ~14F | AESG-6x80 | |
7 | 40 | ~14F | AESG-7x40 | Slightly larger for moderate-sized arteries |
7 | 80 | ~14F | AESG-7x80 | |
7 | 100 | ~14F | AESG-7x100 | |
8 | 60 | ~14–16F | AESG-8x60 | Common size for iliac region |
8 | 80 | ~14–16F | AESG-8x80 | |
8 | 120 | ~16F | AESG-8x120 | Longer coverage for extensive lesion |
9 | 60 | ~16F | AESG-9x60 | For large external iliac or superficial femoral |
9 | 100 | ~16F | AESG-9x100 | |
9 | 150 | ~16F | AESG-9x150 | Extended length for multi-segment disease |
10 | 60 | ~16–18F | AESG-10x60 | Larger diameter for bigger femoral or proximal arteries |
10 | 120 | ~18F | AESG-10x120 | |
10 | 150 | ~18F | AESG-10x150 | |
12 | 80 | ~18F | AESG-12x80 | Very large diameter bridging aneurysms |
12 | 100 | ~18F | AESG-12x100 | |
12 | 150 | ~18F | AESG-12x150 | Maximum coverage for extensive peripheral disease |
12 | 200 | ~18F | AESG-12x200 | Very long stent graft for special cases |
関連商品
-
Atlas 冠動脈ステントシステム ステンレス鋼
続きを読むA ステンレス 冠動脈ステント 堅牢 構造的完全性と 簡単 ルーチンの経皮的冠動脈インターベンション(PCI)において、コスト効率と信頼できる性能のバランスをとりながら、送達可能性を確保する。
-
AngioGraphic Manifold
続きを読むA 回転 または 方向性 アテレクトミー装置 プラーク切除 を増強する。 内腔 バロトラウマを最小限に抑えながら回復する。
-
JaGuarガイドシース
続きを読むA 編み込み ガイドシース トルク 制御と くせ 安全なデバイス・ナビゲーションのための耐性 ペリフェラル または せいりてき 介入する。
-
Atlas Peripheral Stent System
続きを読むA robust peripheral stent platform designed for femoral, iliacあるいは popliteal lesions, ensuring adequate ラジアルサポートと low restenosis rates in PAD interventions.
















































































お問い合わせ&サポート
どのようなお手伝いができますか?
始める前に、あなたを最もよく表す言葉を教えてください。
お問い合わせ&サポート
医療従事者
オンラインお問い合わせフォーム
一般的なご質問や製品に関するご質問は、クイック・オンライン・フォームにご記入ください。追跡用の確認番号と参照番号をお送りします。
製品に関するお問い合わせ
臨床・研究サポート
トレーニングと教育
テクニカルサポート
お問い合わせ&サポート
患者と介護者
オンラインお問い合わせフォーム
一般的なご質問や製品に関するご質問は、クイック・オンライン・フォームにご記入ください。追跡用の確認番号と参照番号をお送りします。
製品の使用と安全性
ご注文とお支払い
サポート&アフターケア
お問い合わせ&サポート
サプライヤー&ディストリビューター
オンラインお問い合わせフォーム
一般的なご質問や製品に関するご質問は、クイック・オンライン・フォームにご記入ください。追跡用の確認番号と参照番号をお送りします。
パートナーシップと契約
物流・配送
コンプライアンスとドキュメンテーション
お問い合わせ&サポート
サプライヤー&ディストリビューター
オンラインお問い合わせフォーム
一般的なご質問や製品に関するご質問は、クイック・オンライン・フォームにご記入ください。追跡用の確認番号と参照番号をお送りします。
プレスリリース&ニュース
インタビュー&声明
イベント&会議
お問い合わせ&サポート
その他 / 一般的なお問い合わせ
オンラインお問い合わせフォーム
一般的なご質問や製品に関するご質問は、クイック・オンライン・フォームにご記入ください。追跡用の確認番号と参照番号をお送りします。
一般情報
ご意見・ご感想
ヘッドクォーター サポートライン
- ワン・ワールド・トレード・センター、285 Fulton Street.ニューヨーク、ニューヨーク州10007、米国
- globalsales@invamed.com
- +1 (347) 535-0630