Atlas 冠動脈ステントシステム ステンレス鋼
A ステンレス 冠動脈ステント 堅牢 構造的完全性と 簡単 ルーチンの経皮的冠動脈インターベンション(PCI)において、コスト効率と信頼できる性能のバランスをとりながら、送達可能性を確保する。
について ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
一般製品仕様
| 仕様 | 詳細 / 価値 |
| 製品名 | Atlas Coronary Stent (Stainless Steel) |
| Stent Type | Balloon-Expandable Coronary Stent |
| 素材 | 316L Stainless Steel (Medical Grade) |
| Strut Thickness | ~100 μm (typical) |
| デザイン | Open-Cell or Hybrid-Cell design (varies by specific model) |
| Nominal Pressure (NP) | ~8–9 atm |
| Rated Burst Pressure (RBP) | ~14–16 atm |
| 配送システム | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
| ガイドワイヤーの適合性 | 0.014" |
| 適応症 | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
| 禁忌事項 | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
| 不妊症 | 無菌(エチレンオキシド) |
| シングルユース | はい |
| 賞味期限 | 2–3 years (based on final packaging and coating, if any) |
| 動作温度 | Recommended 15–25 °C for storage |
詳細サイズオーダー&製品コード
| Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | 商品コード |
| 2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
| 2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
| 2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
| 2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
| 2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
| 2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
| 2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
| 2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
| 2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
| 2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
| 2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
| 2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
| 2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
| 2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
| 2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
| 2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
| 2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
| 2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
| 2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
| 2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
| 2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
| 2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
| 2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
| 2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
| 2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
| 2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
| 2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
| 2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
| 2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
| 2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
| 2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
| 2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
| 3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
| 3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
| 3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
| 3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
| 3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
| 3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
| 3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
| 3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
| 3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
| 3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
| 3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
| 3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
| 3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
| 3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
| 3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
| 3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
| 4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
| 4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
| 4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
| 4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
| 4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
| 4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
| 4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
| 4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
関連商品
-

Stena Multi-Layer Flow Modulator for Peripheral
続きを読むFlow-diverting stent for ペリフェラル arteries, redistributing laminar flow away from diseased vessel segments, aiding aneurysm or side-branch preservation.
-

AngioCATHガイディング・カテーテル
続きを読む高性能ガイディングカテーテル 最適トルク 反応と 精密チップ 形状 冠状 または ペリフェラル インターベンションを行い、安定したデバイスの送達と画像の鮮明さを確保する。
-

Hero 機械式鉛除去システム
続きを読むA 機械的 代替 鉛抽出専用のロック式スタイレットやシースを使用する。 ずらす 線維性付着物の確保 着実 安全に取り外すための牽引力。
-

Peta 胸骨閉鎖プレート
続きを読むA チタン または 合金 胸骨プレート・システム 厳しい 胸骨正中切開後の固定、強化 胸骨の安定性 心臓手術後の感染や剥離のリスクを軽減する。
