AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
禁忌事項
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
製品仕様
| 仕様 | 詳細 / 価値 |
| 製品名 | AngioTENクロージャーデバイス |
| 使用目的 | Percutaneous vascular closure post-catheterization |
| Closure Mechanism | Suture-mediated or collagen plug |
| Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
| Deployment Method | Single-step device insertion and anchor release |
| Hemostasis Time | Typically < 1 minute post-deployment |
| 不妊症 | 滅菌済み、シングルユース |
| 賞味期限 | ~2–3 years at 15–25 °C |
オーダー&サイズマトリックス
| Access Size (F) | Closure Method | Deployment Steps | 商品コード |
| 5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
| 5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
| 8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
| 8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
関連商品
-

SteerCATHステアラブルカテーテル
続きを読むA ステアラブル サポートカテーテル 偏向可能 チップは、複雑な 分船 冠動脈および末梢インターベンションにおけるアクセス。困難な解剖学的構造における交差の成功を促進。
-

Atlas 冠動脈ステントシステム ステンレス鋼
続きを読むA ステンレス 冠動脈ステント 堅牢 構造的完全性と 簡単 ルーチンの経皮的冠動脈インターベンション(PCI)において、コスト効率と信頼できる性能のバランスをとりながら、送達可能性を確保する。
-

Stena Multi-Layer Flow Modulator for Peripheral
続きを読むFlow-diverting stent for ペリフェラル arteries, redistributing laminar flow away from diseased vessel segments, aiding aneurysm or side-branch preservation.
-

Heroレーザー鉛除去システム
続きを読むA レーザーベース 抽出装置 精密 そして セーフ 除去 心臓リード (ペースメーカーまたはICD)の感染症、リードの故障、またはアップグレードの場合。
