Perangkat Revaskularisasi Intrakranial KinG
A penarik stent atau pemulihan aliran perangkat untuk akut stroke iskemikmenangkap dan mengeluarkan gumpalan besar dari arteri intrakranial, dengan cepat memulihkan perfusi.
The King Vascular Revascularization Device adalah stent-based retrieval system designed to restore cerebral blood flow in patients presenting with acute ischemic stroke due to large intracranial vascular occlusion. Incorporating overlapping stent technology, King Vascular effectively captures dan removes thrombus while reinvigorating cerebral perfusion—making it a rapid dan inovatif approach for neurovascular revascularization.
Overlapping Stent Construction
- Enhanced Clot Capture: The device’s multi-layer stent struts increase contact with thrombus, improving retrieval efficacy in large or tough clots.
- Optimized Vessel Conformability: Overlapping cells allow the stent to adapt closely to the tortuous geometry of intracranial arteries, ensuring stable engagement throughout the retrieval process.
Neurovasculature Compatibility
- Broad Anatomical Coverage: Suitable for the internal carotid artery (ICA), M1/M2 segments of the middle cerebral artery, basilardan vertebral arteries.
- Dedicated Neurovascular Materials: Constructed to retain flexibility in smaller-caliber and curved intracranial vessels, reducing the risk of vessel trauma during navigation and retrieval.
Rapid & Innovative Clot Retrieval
- Seamless Deployment: Designed for rapid insertion and retrieval under fluoroscopic guidance, decreasing overall device manipulation.
- High Visibility Markers: Radiopaque markers along the stent struts ensure precise positioning and real-time feedback under angiography.
Flow Restoration
- Improved Patency: The stent lattice temporarily expands the occluded segment, promoting partial or complete flow restoration even before full clot retrieval.
- Multiphase Extraction: Operators can perform multiple passes if needed, targeting residual thrombus while maintaining cerebral perfusion.
- Enhanced Clot Capture: The device’s multi-layer stent struts increase contact with thrombus, improving retrieval efficacy in large or tough clots.
- Optimized Vessel Conformability: Overlapping cells allow the stent to adapt closely to the tortuous geometry of intracranial arteries, ensuring stable engagement throughout the retrieval process.
- Broad Anatomical Coverage: Suitable for the internal carotid artery (ICA), M1/M2 segments of the middle cerebral artery, basilardan vertebral arteries.
- Dedicated Neurovascular Materials: Constructed to retain flexibility in smaller-caliber and curved intracranial vessels, reducing the risk of vessel trauma during navigation and retrieval.
- Seamless Deployment: Designed for rapid insertion and retrieval under fluoroscopic guidance, decreasing overall device manipulation.
- High Visibility Markers: Radiopaque markers along the stent struts ensure precise positioning and real-time feedback under angiography.
- Improved Patency: The stent lattice temporarily expands the occluded segment, promoting partial or complete flow restoration even before full clot retrieval.
- Multiphase Extraction: Operators can perform multiple passes if needed, targeting residual thrombus while maintaining cerebral perfusion.
Spesifikasi Produk
Spesifikasi | Detail / Nilai |
Nama Produk | Perangkat Revaskularisasi Intrakranial KinG |
Tujuan Penggunaan | Acute ischemic stroke treatment in large vessel occlusion (LVO), mechanical thrombectomy within intracranial arteries |
Device Type | Stent retriever or revascularization device with self-expanding design |
Bahan | Medical-grade nitinol (Nickel-Titanium) or cobalt-chromium alloy |
Mekanisme Penyebaran | Microcatheter-based insertion, typically 0.021”–0.027” ID |
Penanda Radiopak | Distal and proximal markers for fluoroscopic visualization |
Length & Diameter Range | ~15–40 mm length, 3–6 mm diameter (depending on specific code) |
Kompatibilitas | Guide catheter or sheath (≥ 5F–6F) for intracranial access, 0.014” wire guidance |
Kemandulan | Steril, Sekali Pakai |
Umur simpan | ~3–5 years at 15–25 °C in sealed packaging |
Indikasi Klinis | Large vessel occlusion in the anterior or posterior circulation, e.g., M1, M2, ICA terminus, basilar artery |
Kontraindikasi | Extreme vessel tortuosity, advanced intracranial stenosis, known nickel allergy |
Matriks Pemesanan & Ukuran
Device Diameter (mm) | Device Length (mm) | Microcatheter ID (inch) | Kode Produk | Catatan |
3.0 | 20 | 0.021" | KNG-3.0x20-021 | Smaller stent retriever for distal M2 or narrower vessels |
3.0 | 28 | 0.021" | KNG-3.0x28-021 | Extended length, same diameter |
4.0 | 20 | 0.021" | KNG-4.0x20-021 | Mid-range diameter, short retriever for M1 |
4.0 | 28 | 0.027" | KNG-4.0x28-027 | Longer device, larger microcatheter needed |
4.5 | 28 | 0.027" | KNG-4.5x28-027 | Wider diameter for proximal ICA or large M1 |
4.5 | 35 | 0.027" | KNG-4.5x35-027 | Extended coverage in wide vessel occlusions |
6.0 | 40 | 0.027" | KNG-6.0x40-027 | Largest diameter for basilar tip or wide ICA |