Keeper Endovascular Snare
A multi-loop snare retrieval device for foreign body atau embolus capture, ensuring aman engagement and withdrawal from vascular lumens.
Keeper Endovascular Snare by INVAMED is a single-use, sterile device engineered to capture and retrieve intravascular foreign objects, from dislodged stents or guidewire fragments to thrombosis and other undesirable materials in the vascular system. With an innovative loop design and low-profile catheter introduction, the Keeper Snare provides precise control, maximum radial force, and minimized trauma—streamlining procedures in both arterial and venous settings.
Flexible Snare Loop Geometry
- Constructed from high-tensile nitinol or stainless-steel wires in various loop diameters for optimal capture potential.
- Retains shape memory and radial strength even after multiple manipulation cycles, supporting consistent retrieval.
Ergonomic Catheter Delivery
- Low-profile catheter sheath simplifies femoral, radial, or brachial access.
- Catheter tip and snare loop are radiopaque, facilitating fluoroscopic or angiographic visualization and precise target approach.
Enhanced Capture and Control
- The snare loop compresses or expands under operator control, securely gripping foreign bodies or occlusive elements without risk of fragmenting them further.
- A dedicated handle or torque device (depending on model) provides precision in loop rotation and retraction.
Minimally Invasive Retrieval
- Reduces or eliminates the need for open surgical extraction, shortening patient recovery times and lowering complication risks.
- Effective for broken guidewires, catheter fragments, or other intraluminal materials that must be removed promptly to avoid embolization or vascular injury.
Broad Range of Indications
- Suitable for arterial or venous retrieval in peripheral vessels, central vasculature, or even select cardiac chambers if indicated.
- Helpful in addressing intravascular coil misplacements, filter retrievals, or spontaneous foreign body presence.
Spesifikasi Produk
Spesifikasi | Detail / Nilai |
Nama Produk | Keeper Endovascular Snare |
Tujuan Penggunaan | Retrieval of foreign bodies, dislodged stents, or thrombus fragments from vascular lumens |
Snare Material | Nitinol or Stainless Steel loop with radiopaque marker |
Loop Diameter Range | ~2–35 mm (depending on vessel size) |
Shaft Length | 80–120 cm (various) |
Kompatibilitas Guidewire | 0.018” or 0.035” (check model) |
Sheath Compatibility | 4–6F typical |
Kemandulan | Steril, Sekali Pakai |
Umur simpan | ~3 years, 15–25 °C storage |
Matriks Pemesanan & Ukuran
Loop Diameter (mm) | Shaft Length (cm) | Guidewire Size | Kode Produk |
5 | 80 | 0.018" | KEE-5-80-018 |
10 | 80 | 0.018" | KEE-10-80-018 |
15 | 100 | 0.035" | KEE-15-100-035 |
20 | 100 | 0.035" | KEE-20-100-035 |
25 | 120 | 0.035" | KEE-25-120-035 |
35 | 120 | 0.035" | KEE-35-120-035 |
Produk Terkait
-
Rotablator TemREN
Baca selengkapnyaA rotasi sistem trombektomi atau aterektomi yang menampilkan kecepatan tinggi gerinda ke menggiling atau menghilangkan plak yang mengapur, memastikan perluasan lumen yang lebih baik untuk penempatan stent.
-
Sistem Stent Koroner Baja Tahan Karat Atlas
Baca selengkapnyaA baja tahan karat penawaran stent koroner kuat integritas struktural dan mudah untuk intervensi koroner perkutan rutin (PCI), menyeimbangkan efisiensi biaya dengan kinerja yang andal.
-
Extender Obat Eluting Kateter Balon PTCA Paclitaxel
Baca selengkapnyaA dilapisi paclitaxel kateter balon koroner yang ditujukan untuk mengurangi restenosis selama angioplasti koroner transluminal perkutan (PTCA), untuk memastikan pengiriman obat yang efektif ke dinding pembuluh darah.
-
Atlas Coronary Stent Graft System
Baca selengkapnyaA covered coronary stent system providing extraluminal sealing in perforations atau pseudoaneurysms, maintaining coronary patency while preventing extravasation.