Atlas शिरापरक स्टेंट

जैवसंगत धातु मिश्रधातुओं से निर्मित एक विशेष प्रत्यारोपण प्रणाली, जिसे रक्त वाहिकाओं की खुली स्थिति को बनाए रखते हुए, रक्त प्रवाह में सुधार करते हुए, तथा दीर्घकालिक शिरापरक अपर्याप्तता के लक्षणों को कम करते हुए शिरापरक अवरोधों के उपचार के लिए डिजाइन किया गया है।

The Atlas™ Venous Stent, introduced by आक्रमण-ए वैश्विक चिकित्सा उपकरण निर्माता—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a आत्म का विस्तार nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting टिकाऊ patency in challenging venous anatomies.

Self-Expanding Nitinol Framework

Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.

Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.

Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.

Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.

Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.

Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.

Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.

Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.

Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.

Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.

Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.

Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.

Technical Specifications

विनिर्देश विस्तार / मूल्य
प्रोडक्ट का नाम Atlas™ Venous Stent
Stent Material Nitinol (nickel-titanium) self-expanding alloy
तैनाती तंत्र Over-the-wire via introducer sheath (typically 6F–9F, model-specific)
रेडियल बल Moderate to high, designed to resist extrinsic compression
स्टेंट व्यास रेंज ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes
Stent Length Range ~40–120 mm, accommodating short or long-segment lesions
रेडियोपेक मार्कर Proximal and distal markers for fluoroscopic visualization
बाँझपन Sterile, single use
शेल्फ जीवन ~3–5 years if stored at 15–25 °C
नैदानिक संकेत Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency

Size & Ordering Matrix

Stent Diameter (mm) Stent Length (mm) Sheath Compatibility (F) उत्पाद कोड नोट्स
10 40 6एफ AVS-10x40-6F Smaller diameter for narrower veins or moderate lesions
10 60 6एफ AVS-10x60-6F Slightly longer coverage in the same diameter
14 60 7एफ AVS-14x60-7F Popular mid-range diameter for common iliofemoral lesions
14 80 7एफ AVS-14x80-7F Extended length for multi-segment stenoses
16 80 8F AVS-16x80-8F Enhanced diameter for advanced venous outflow compromise
16 100 8F AVS-16x100-8F Longer coverage in larger veins
20 120 9 फ AVS-20x120-9F Maximum diameter & length for extensive venous pathology