HyperTiss Set d'hypothermie intracavitaire pour le traitement du cancer de la vessie
Système médical avancé conçu pour administrer une hypothermie contrôlée directement dans la cavité vésicale, améliorant les résultats thérapeutiques dans le traitement du cancer de la vessie en augmentant la sensibilité de la tumeur à la chimiothérapie et en réduisant les taux de récidive.
Le HyperTiss Intracavitary Hypothermia Set offers a multifactorial approach to bladder tumor management by combining chemotherapy with targeted hyperthermia in a controlled, patient-friendly delivery system. Through a specialized Three-Way Foley Silicone Catheter and advanced temperature control technology, HyperTiss ensures precise thermal and drug regulation—optimizing chemo-hyperthermia’s efficacy against cancerous tissue within the bladder while prioritizing patient safety and comfort.
System Components & Design
Three-Way Foley Silicone Catheter
- High-Quality Silicone: Minimizes irritation to the bladder wall, promoting patient tolerance during extended intravesical therapy.
- Multi-Port Access: Enables drug instillation, temperature monitoring, and continuous fluid exchange with minimal instrumentation.
Connection Connectors & Two-Way Stopcock
- Secure Fluid Pathways: Prevents leakage or accidental disconnection, providing stable infusion and drainage ports for the anticancer solution.
- Two-Way Stopcock: Offers operator-friendly toggling between infusion, drainage, or sealed modes during the procedure.
Heat Probe
- Precise Temperature Regulation: Monitors and maintains fluid temperature within a 41–44°C range (±0.2°C) per physician protocol.
- Optimized Hyperthermia Delivery: Ensures uniform heat distribution across the bladder mucosa, enhancing drug uptake.
Clamp, Medical Grade PVC Tubing & Bag
- Fluid Management: Simplifies infusion, drainage, or recirculation processes for delivering heated chemotherapy solutions.
- Transparent & Latex-Free: Allows clinicians to observe fluid levels and flow conditions, supporting safe handling.
Tubes en silicone
- Flexible, Atraumatic: Minimizes mechanical stress on the bladder or the infusion line, enhancing patient safety and comfort.
- Biocompatible Construction: Resists kinking and maintains consistent fluid passage even under repeated bending.
Therapeutic Rationale: Chemo-Hyperthermia
Synchronized Temperature & Drug Delivery
- HypertISS: (Hypothermia might be a mis-labelling or it’s “HyperTiss” but anyway) By raising local tissue temperature to 41–44°C, the synergy between heat and chemotherapeutic solutions intensifies cancer cell death.
- Favorable Tissue Response: Hyperthermia triggers changes in tumor vasculature, enhancing chemotherapeutic penetration and susceptibility of malignant cells to cytotoxic agents.
Reduced Recurrence Rates
- Improved Oncologic Control: Enhanced tissue drug levels plus disruption of tumor cell defense mechanisms can lower progression or relapse of bladder tumors.
- Better Resource Allocation: Effective local therapy can lessen the need for extensive systemic treatments, cutting down cost and toxicity profiles.
Clinical Advantages & Indications
Enhancing Chemotherapy Efficacy
- Targeted Hyperthermia: Elevates local temperature in the bladder to potentiate chemotherapeutic effects, thereby improving tumor cell kill rates.
- Increased Drug Penetration: Heated environment encourages deeper and more consistent uptake of anticancer agents.
Multifactorial Mode of Action
- Combination of Heat & Ionized Molecule Delivery: Creates a synergy that overcomes drug resistance and fosters thorough coverage of bladder lesions.
- Reduced Systemic Toxicity: Local administration confines drug exposure mainly to the bladder region, potentially lowering systemic side effects.
User-Friendly & Patient-Centric
- Outpatient/Local Anesthesia: Many procedures can be performed on a short-stay basis, optimizing hospital resources and improving patient quality of life.
- Reliable Monitoring & Control: Comprehensive alarm systems plus real-time temperature feedback maintain high standards of safety.
Robust Safety Measures
- Automatic Safety Shutdown: Mitigates risk if unexpected temperature or pressure fluctuations occur.
- Alarm Alerts: Minimizes operator error and ensures the procedure remains within the safe therapeutic window.
Produits similaires
-
UroGuide Fils-guides
Continuer la lectureFils-guides conçus avec précision pour offrir un contrôle et une flexibilité exceptionnels pendant les procédures urologiques, assurant une navigation fluide et un meilleur accès aux voies urinaires.
-
Lotus Single Lumen & Double Lumen (RX) PTCA Microcatheter
Continuer la lectureMicrocatheters conçu pour coronaire or peripheral lesion crossing, offering single- or double-lumen configurations for guidewire exchange, contrast injection, or subselective lesion access.
-
Système de stent coronaire à élution médicamenteuse ATLAS Cobalt Chromium
Continuer la lectureA cobalt-chrome pose d'un stent coronaire résistance radiale durable et excellente traçabilité, adapté à complexe ou calcifié des lésions coronaires tout en garantissant un recul minimal.
-
Système d'endoprothèse coronaire Atlas
Continuer la lectureA stent coronaire couvert système fournissant extraluminal sceller perforations ou pseudo-anévrismesL'utilisation d'un système d'aspiration à l'aide d'une pompe à insuline permet de maintenir la perméabilité coronaire tout en prévenant l'extravasation.