Atlas Coronary Stent System Acier inoxydable
A acier inoxydable offre d'endoprothèses coronaires robuste l'intégrité structurelle et facile pour les interventions coronariennes percutanées (ICP) de routine, en conciliant rentabilité et fiabilité des performances.
Le ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Spécifications générales du produit
| Spécifications | Détail / Valeur |
| Nom du produit | Atlas Coronary Stent (Stainless Steel) |
| Stent Type | Balloon-Expandable Coronary Stent |
| Matériau | 316L Stainless Steel (Medical Grade) |
| Strut Thickness | ~100 μm (typical) |
| Conception | Open-Cell or Hybrid-Cell design (varies by specific model) |
| Nominal Pressure (NP) | ~8–9 atm |
| Rated Burst Pressure (RBP) | ~14–16 atm |
| Système de livraison | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
| Compatibilité des fils-guides | 0.014” |
| Indications | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
| Contre-indications | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
| Stérilité | Stérile (oxyde d'éthylène) |
| Usage unique | Oui |
| Durée de conservation | 2–3 years (based on final packaging and coating, if any) |
| Température de fonctionnement | Recommended 15–25 °C for storage |
Commande détaillée en fonction de la taille et codes produits
| Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Code produit |
| 2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
| 2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
| 2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
| 2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
| 2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
| 2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
| 2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
| 2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
| 2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
| 2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
| 2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
| 2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
| 2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
| 2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
| 2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
| 2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
| 2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
| 2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
| 2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
| 2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
| 2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
| 2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
| 2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
| 2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
| 2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
| 2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
| 2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
| 2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
| 2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
| 2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
| 2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
| 2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
| 3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
| 3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
| 3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
| 3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
| 3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
| 3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
| 3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
| 3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
| 3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
| 3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
| 3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
| 3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
| 3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
| 3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
| 3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
| 3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
| 4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
| 4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
| 4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
| 4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
| 4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
| 4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
| 4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
| 4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Produits similaires
-

Cathéter à ballonnet PTCA Extender
Continuer la lectureA standard haute pression ballon coronaire conçu pour prédilatation des lésions ou autonome angioplastieLes profils de gonflage sont précis et les profils de croisement sont réduits.
-

Video Laryngoscope
Continuer la lectureDispositif médical de haute précision composé de matériaux durables et biocompatibles, conçu pour permettre une meilleure visualisation des voies aériennes pendant l'intubation, améliorant ainsi la sécurité et l'efficacité des procédures de gestion des voies aériennes.
-

Système d'endoprothèse coronaire Atlas
Continuer la lectureA stent coronaire couvert système fournissant extraluminal sceller perforations ou pseudo-anévrismesL'utilisation d'un système d'aspiration à l'aide d'une pompe à insuline permet de maintenir la perméabilité coronaire tout en prévenant l'extravasation.
-

SteerCATH Cathéter orientable
Continuer la lectureA orientable soutenir le cathéter avec déformable de la pointe, conçue pour des applications complexes ou vaisseau de branchement dans les interventions coronaires et périphériques. Améliore la réussite des croisements dans les anatomies difficiles.
