AngioHAND Cathéter d'élimination des caillots
A manipulé à la main dispositif d'aspiration mécanique permettant une extraction de caillots par le biais d'un manuel simplifiant ainsi les procédures de thrombectomie aiguë.
The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.
Braided Balloon-Shaped Capture
- Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
- Ensures robust clot entrapment without excessive fragmentation or distal embolization.
Manual Vacuum Mechanism
- Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
- Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
Rapid & Intuitive Thrombectomy
- Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
- One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
Enhanced Safety & Vessel Protection
- Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
- Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
Multiple Clinical Indications
- Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
- Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
- Use in emergent or elective procedures where fast mechanical clot extraction is paramount.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | AngioHAND Cathéter d'élimination des caillots |
Utilisation prévue | Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels |
Conception du cathéter | Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip |
Gamme de diamètres extérieurs | ~5F–7F (depending on model) |
Lumen Inner Diameter | Large bore optimized for clot aspiration |
Longueur de travail | ~80–120 cm (varies by product code) |
Configuration des conseils | Tapered or funnel-shaped tip to facilitate clot ingress |
Radiopaque Marker | Distal marker band for fluoroscopic location |
Vacuum Mechanism | Manual hand-syringe or integrated vacuum lock (no external pump required) |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2–3 years at 15–25 °C |
Indications cliniques | Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts |
Contre-indications | Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy |
Commande et matrice des tailles
Diamètre extérieur (F) | Longueur de travail (cm) | Tip Style | Code produit | Notes |
5F | 80 | Tapered Soft Tip | ANG-HND-5F-80-TS | Smaller diameter for coronary or distal peripheral |
5F | 100 | Funnel Tip | ANG-HND-5F-100-FN | Moderate length, manual vacuum approach |
6F | 80 | Tapered Soft Tip | ANG-HND-6F-80-TS | Common size for peripheral thrombus aspiration |
6F | 120 | Funnel Tip | ANG-HND-6F-120-FN | Extended length for deeper occlusion sites |
7F | 100 | Tapered Soft Tip | ANG-HND-7F-100-TS | Larger lumen for heavier clot burden |
7F | 120 | Funnel Tip | ANG-HND-7F-120-FN | Maximum length plus funnel design for wide clot removal |
Produits similaires
-
Atlas Endoprothèse veineuse
Continuer la lectureSystème d'implant spécialisé composé d'alliages métalliques biocompatibles, conçu pour traiter les obstructions veineuses en maintenant la perméabilité des vaisseaux, en améliorant le flux sanguin et en soulageant les symptômes de l'insuffisance veineuse chronique.
-
Viper Cathéter de thrombolyse ULTRA
Continuer la lectureUn ultra cathéter de perfusion spécialisé pour direct l'administration de thrombolytiques, avec multi-trous de distribuer uniformément les médicaments dans de vastes segments de coagulation.
-
InWIRE Fils guides périphériques
Continuer la lectureMultiple périphérique les configurations de fils (hydrophiles, rigides, à longueur d'échange) qui facilitent sûr la traversée de lésions complexes ou calcifiées et la garantie d'un support stable du dispositif.
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Continuer la lectureA rotationnel qui comprend un système de pointe de la feuille conception pour mécanique fragmentation du caillot plus fort des capacités d'aspiration dans les occlusions veineuses ou artérielles profondes.