Peta Plaque de fermeture du sternum
A titane ou alliage système de plaque sternale fournissant rigide fixation après sternotomie médiane, améliorant ainsi la qualité de l'air. stabilité sternale et de réduire les risques d'infection ou de déhiscence après une chirurgie cardiaque.
Le PetaⓇ Sternum Closure Plate addresses the challenges associated with fixating a 90-degree sternal incision or rib osteotomy through an anatomically contoured, low-profile design. Constructed from a highly biocompatible Ti-6Al-4V-ELI alloy and featuring a user-friendly locking block, PetaⓇ provides secure and re-tensionable closure, ensuring optimal stability and patient comfort.
Low-Profile Design
- Minimally Invasive Access: The plate’s thin profile accommodates incisions in tight anatomical spaces, lessening postoperative discomfort and risk of soft tissue irritation.
- Anatomical Contouring: Engineered to conform seamlessly to the curvature of the sternum or rib, enhancing implant stability while preserving natural bone alignment.
Locking Block with Ti-6Al-4V-ELI Alloy
- Highly Biocompatible: The titanium alloy demonstrates excellent osseointegration and minimal inflammatory response, making it suitable for long-term surgical implants.
- Secure Lock Mechanism: Once fixed by the locking-block screw, there is no risk of self-loosening or accidental opening—critical for maintaining consistent compression across the osteotomy site.
- Re-Tension Capability: The locking block screw can be loosened intraoperatively to re-tension the plate, streamlining adjustments and shortening operating room time.
- Secure Lock Mechanism: Once fixed by the locking-block screw, there is no risk of self-loosening or accidental opening—critical for maintaining consistent compression across the osteotomy site.
Magnetic Resonance (MR) Compatibility
- Advanced Imaging Safety: MR compatibility ensures that patients requiring postoperative MRI can undergo imaging with minimal artifact and without necessitating plate removal.
- Clinically Versatile: This feature is especially valuable for complex cases that demand ongoing multimodal imaging for diagnosis or follow-up.
Technical Advantages
Enhanced Stability
The rigid fixation achieved through titanium alloy construction and a low-profile locking system improves bone healing and reduces micromotion, crucial factors in preventing non-union or delayed union.
Reduced Postoperative Pain
An anatomically contoured plate can decrease soft tissue irritation, potentially lowering patient discomfort and accelerating recovery timelines.
Surgeon-Controlled Tensioning
The ability to modify or re-tension the locking block screw intraoperatively offers precise control over compression, alignment, and overall surgical outcome.
Versatility in Plate Placement
Multiple plate lengths and shapes (depending on the system’s available catalog) enable surgeons to tailor the fixation construct to specific patient anatomies and surgical approaches.
Spécifications générales du produit
Spécifications | Détail / Valeur |
Nom du produit | Peta Plaque de fermeture du sternum |
Utilisation prévue | Rigid fixation of the sternum post sternotomy (open-heart surgery, thoracic intervention) |
Plate Material | Titanium alloy (e.g., Ti-6Al-4V ELI) or Stainless Steel (316L), depending on product line |
Plate Thickness | ~1.0–1.5 mm (typical range; verify your actual specs) |
Plate Width | ~10–15 mm (to provide adequate coverage over sternal edges) |
Hole Configuration | Round or oval holes for bone screws, spaced at intervals for adjustable fixation |
Screw Compatibility | Typically 2.4 mm or 2.7 mm diameter cortical bone screws (confirm actual) |
Anatomical Shape | May include slightly contoured or “anatomical” plates for better sternal conformance |
Compatibilité MR | MR Conditional or Safe, depending on final metal composition |
Stérilité | Sterile (Gamma or EO) |
Usage unique | Oui |
Durée de conservation | ~5 years if packaging remains sealed |
Indications cliniques | Midline sternotomy closure, sternal stability improvement, prevention of dehiscence or infection |
Contre-indications | Grossly insufficient bone stock, active sternal infection (needing further debridement first), etc. |
Peta Sternal Plates
Plate Length (mm) | Hole Count | Thickness (mm) | Plate Shape | Code produit | Notes |
40 | 4 | 1.0 | Straight | PETA-40-4-1.0-S | Short plate for partial sternal closure segments |
40 | 4 | 1.2 | Curved | PETA-40-4-1.2-CV | Slight curvature to match upper manubrium |
50 | 5 | 1.0 | Straight | PETA-50-5-1.0-S | Medium length, minimal thickness |
50 | 5 | 1.2 | Slightly contoured | PETA-50-5-1.2-SC | Subtle sternal conformance |
60 | 6 | 1.0 | Straight | PETA-60-6-1.0-S | Extended length for broader sternums |
60 | 6 | 1.2 | Curved | PETA-60-6-1.2-CV | Curved design for mid-lower sternum |
60 | 8 | 1.5 | Straight | PETA-60-8-1.5-S | Additional hole count for robust fixation, thicker plate version |
70 | 6 | 1.0 | Slightly contoured | PETA-70-6-1.0-SC | Longer coverage, minimal thickness |
70 | 8 | 1.2 | Curved | PETA-70-8-1.2-CV | More hole options for multi-screw stability, moderate thickness |
80 | 8 | 1.2 | Straight | PETA-80-8-1.2-S | Extended length for full sternum coverage |
80 | 10 | 1.5 | Slightly contoured | PETA-80-10-1.5-SC | Thicker plate, extended length, multiple hole fixations |
90 | 10 | 1.2 | Curved | PETA-90-10-1.2-CV | Very long plate for entire sternotomy line in certain surgeries |
90 | 12 | 1.5 | Straight | PETA-90-12-1.5-S | Maximum hole count for comprehensive fixation, thicker plate |
Produits apparentés
-
GuideX Cathéter d'extension
Lire la suiteUn extension ou l'offre de cathéters "mère-enfant". un soutien renforcé et atteindre à l'intérieur d'une zone tortueuse ou distal segments coronaires/périphériques, ce qui permet une navigation stable de l'appareil.
-
Hero LASER Système de suppression du plomb
Lire la suiteA à base de laser dispositif d'extraction permettant précis et sûr suppression de sondes cardiaques (stimulateur cardiaque ou DCI) en cas d'infection, de dysfonctionnement de la sonde ou de mise à niveau.
-
Delta Système de dénervation rénale
Lire la suiteA radiofréquence-Système de cathéter basé sur la technologie de l'ADN, spécialisé dans la fabrication de cathéters. sympathique rénal dénervation en hypertension résistanteL'insuline, qui réduit l'activité nerveuse, permet de contrôler la tension artérielle.
-
TemREN Rotablator
Lire la suiteA rotationnel système de thrombectomie ou d'athérectomie comprenant à grande vitesse bavures à broyage ou retirer la plaque calcifiée, assurant ainsi une meilleure expansion de la lumière pour la mise en place du stent.