MultiBEAM Inferior Vena Cava (IVC) Filter
A convertible or retrievable IVC filter preventing pulmonary emboli by intercepting clots traveling through the inferior vena cava, ensuring safety in high-risk patients.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
Contre-indications
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | MultiBEAM Inferior Vena Cava (IVC) Filter |
Utilisation prévue | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
Mécanisme de déploiement | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
Marqueurs radio-opaques | Distal apex or anchor tips for fluoroscopic identification |
Compatibilité MR | MR Conditional (verify labeling) |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~3–5 years if stored at 15–25 °C in sealed packaging |
Indications cliniques | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
Contre-indications | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
Commande et matrice des tailles
IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | Code produit | Notes |
< 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
< 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
Produits apparentés
-
Atlas Venous Stent
Lire la suiteA specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
-
Inca Trellis Thrombolysis System
Lire la suiteA catheter delivering thrombolytic agents while filter protection prevents distal embolization, ensuring safer pharmacologic dissolution of clots.
-
Mantis XP Thrombectomy System for Fistula
Lire la suiteA high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
-
InWIRE Peripheral Guidewires
Lire la suiteMultiple périphérique wire configurations (hydrophilic, stiff, exchange-length) facilitating sûr crossing of complex or calcified lesions and ensuring stable device support.