DolphinPro Cathéter de soutien
A aide à la traversée cathéter pour complexe des lésions périphériques ou coronaires, présentant une arbre renforcé et hydrophile pour faciliter l'administration du dispositif.
DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.
Stainless Steel Double-Braiding
A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.
Optimal Push Transition
Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.
Small Crossing Profile
Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.
Telescope Technique
DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.
Broad Clinical Utility
Ideal for femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.
Contre-indications
- Extreme vessel tortuosity or diameter below specification
- Active infection or severe vessel dissection precluding wire-based recanalization
- Patient conditions contraindicating endovascular procedures
Spécifications techniques
Spécifications | Détail / Valeur |
Nom du produit | DolphinPro Cathéter de soutien |
Utilisation prévue | Lesion crossing and support in femoro-popliteal & BTK interventions |
Shaft Construction | Stainless Steel Double-Braiding with advanced polymer coatings |
Proximal Diameter | Low-profile crossing design; verify available French sizes based on region |
Distal Tip Profile | Tapered, reinforced tip for improved guidewire entry and lesion crossing |
Length Options | Common lengths ranging from 65 cm to 150 cm; additional lengths upon request |
Compatibilité des fils-guides | Typically 0.014” or 0.018” (verify exact compatibility) |
Radiopacity | Radiopaque distal tip and markers for precise visualization |
Stérilité | Provided sterile (single use) |
Indications cliniques | Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature |
Size & Ordering Matrix
French Size | Usable Length (cm) | Guidewire | Tip Shape | Code produit | Notes |
2.4 – 2.6 | 65 / 90 / 135 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Suited for BTK interventions requiring flexible distal tip and stable proximal support |
2.4 – 2.6 | 100 / 150 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Extended length for deeper lesions in SFA or popliteal region |
3.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
4.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
5.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
6.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
7.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
Produits apparentés
-
Viper Cathéter de thrombolyse ULTRA
Lire la suiteUn ultra cathéter de perfusion spécialisé pour direct l'administration de thrombolytiques, avec multi-trous de distribuer uniformément les médicaments dans de vastes segments de coagulation.
-
Atlas Endovascular Peripheral Stent Graft (endoprothèse périphérique)
Lire la suiteA stent périphérique couvert offre de greffe sécurisé occlusion d'anévrismes ou de lésions occlusives dans les iliaque ou fémoral réduisant ainsi le risque de rupture ou de ré-occlusion.
-
Stena Modulateur de débit multicouche pour périphériques
Lire la suiteDéviation de flux stent pour périphérique artères, redistribution laminaire le flux s'éloigne des segments de vaisseaux malades, ce qui facilite la préservation des anévrismes ou des branches latérales.
-
Keeper Collet endovasculaire
Lire la suiteA multi-boucles dispositif de récupération de collet pour corps étranger ou embole capturer, garantir sécurisé l'engagement et retrait des lumières vasculaires.