کاتتر پشتیبانی عبوری کم ارتفاع Dolphin PRO
الف کم بازدید عبور کاتتر با افزایش قابلیت فشار و قابلیت ردیابی، طراحی شده برای تنگ یا به شدت کلسیفیه شده ضایعات در شریانهای کرونری یا محیطی.
The Dolphin® Pro Low Profile Crossing Support Catheter developed by Invamed, a global medical device manufacturer—is designed for precise and efficient guidewire support in complex vascular interventions. Built to navigate tight or tortuous anatomies, this low-profile catheter integrates three radiopaque markers along the distal shaft, enabling improved positional awareness and accurate lesion crossing in both peripheral arteries.
Triple Marker System
- Three strategically placed markers along the distal segment enhance fluoroscopic visibility, facilitating precise depth and orientation checks when crossing tough occlusions.
Low-Profile Construction
- Optimized for smaller vessel diameters or micro-channel crossing, reducing friction and minimizing vessel trauma.
High Pushability & Torque
- Braided or coiled shaft provides robust support while retaining flexibility, ensuring stable guidewire manipulation through heavily calcified or occluded segments.
Multi-Use Applications
- Ideal for peripheral artery disease (PAD) or complex coronary lesion crossing, offering consistent performance in subintimal or luminal track approaches.
مشخصات عمومی محصول
مشخصات | جزئیات / ارزش |
نام محصول | کاتتر پشتیبانی عبوری کم ارتفاع Dolphin PRO |
کاربرد مورد نظر | Facilitates wire crossing in complex or chronic total occlusion (CTO) lesions, primarily in smaller or distal vessels |
طراحی کاتتر | Ultra-low profile shaft, possible braided or coiled backbone for torque and push, hydrophilic coating (if applicable) |
مواد | پباکس/پلیآمید با تقویتکننده فولاد ضد زنگ یا نیتینول |
محدوده قطر بیرونی | ~1.8–2.3 Fr (depending on model) |
لومن داخلی | Typically 0.014” wire compatibility |
طول کار | ~80–150 cm, depending on specific code |
پیکربندی نوک | Tapered or angled tip, radiopaque distal marker |
Marker Bands | 1–2 marker bands near the distal end for precise fluoroscopic visualization |
سازگاری با غلاف | Typically 4F or smaller introducer (due to low-profile design) |
استریل بودن | استریل (اتیلن اکسید) |
یکبار مصرف | بله |
ماندگاری | ~2–3 years if stored in sealed packaging at 15–25 °C |
علائم بالینی | Complex lesion crossing in smaller or distal vessels (BTK arteries, small coronaries, etc.), fine device support |
موارد منع مصرف | Extremely calcified or tortuous anatomies beyond safe manipulation, known device material allergies |
Dolphin PRO Low Profile
Fr Size | طول کار (سانتی متر) | Tip Style | کد محصول | یادداشتها |
1.8 Fr | 80 | Straight | DLP-1.8-80-ST | Ultra-low OD for very small vessels or subintimal approaches |
1.8 Fr | 80 | Tapered | DLP-1.8-80-TP | Tapered tip for crossing tight CTO caps |
1.8 Fr | 100 | Straight | DLP-1.8-100-ST | Longer length for distal BTK or small coronary tracks |
2.0 Fr | 80 | Angled | DLP-2.0-80-AN | Slightly bigger OD, angled tip for branch approach |
2.0 Fr | 100 | Straight | DLP-2.0-100-ST | Balanced push + track in small peripheral arteries |
2.0 Fr | 135 | Tapered | DLP-2.0-135-TP | Extended length for multi-segment crossing |
2.2 Fr | 80 | Straight | DLP-2.2-80-ST | Enhanced lumen for 0.014” wire plus small device passage |
2.2 Fr | 100 | Angled | DLP-2.2-100-AN | Angled tip for difficult side branches |
2.2 Fr | 135 | Tapered | DLP-2.2-135-TP | Tapered distal tip + long working length |
2.3 Fr | 135 | Straight | DLP-2.3-135-ST | Largest OD in the low-profile series, for moderate vessel size |
2.3 Fr | 150 | Tapered | DLP-2.3-150-TP | Maximum length in low-profile design |
محصولات مرتبط
-
دام اندوواسکولار Keeper
اطلاعات بیشترالف چند حلقهای دستگاه بازیابی دام برای جسم خارجی یا آمبولی گرفتن، اطمینان حاصل کردن امن نامزدی و برداشت از لومنهای عروقی.
-
سیستم آترکتومی محیطی TemREN
اطلاعات بیشترالف چرخشی یا جهت دار دستگاه آترکتومی مخصوص برداشتن پلاک در شریانهای محیطی، افزایش مییابد لومن ترمیم ضمن به حداقل رساندن باروترومای ناشی از ضربه (باروتروما).
-
سیستم استنت محیطی Atlas
اطلاعات بیشترقوی استنت محیطی پلتفرم طراحی شده برای فمورال, ایلیاک، یا پوپلیتیال ضایعات، تضمین کافی پشتیبانی شعاعی و کم میزان تنگی مجدد در مداخلات PAD.
-
دستگاه بسته شدن AngioTEN
اطلاعات بیشترالف از راه پوست سیستم بسته شدن عروق برای شریانی یا وریدی دسترسی به سایتها، فعال کردن امن هموستاز پس از کاتتریزاسیون یا اقدامات مداخلهای.