ATLAS Σύστημα στεφανιαίων στελεχών που εκλύουν φάρμακα Χρώμιο κοβαλτίου
A κοβάλτιο-χρώμιο παροχή στεφανιαίου stent ανθεκτική ακτινική αντοχή και άριστη ιχνηλασιμότητα, κατάλληλο για σύνθετο ή αποσαθρωμένο στεφανιαίες βλάβες, εξασφαλίζοντας παράλληλα την ελάχιστη ανάκρουση.
Το ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
Προδιαγραφές | Λεπτομέρεια / Αξία |
Όνομα προϊόντος | Atlas Coronary Stent (Cobalt Chromium) |
Stent Type | Balloon-Expandable Coronary Stent |
Υλικό | Cobalt-Chromium Alloy |
Strut Thickness | ~80 µm (typical) |
Σχεδιασμός | Open-cell or hybrid-cell architecture (depending on exact model) |
Nominal Pressure (NP) | 9–10 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Συμβατότητα οδηγού σύρματος | 0.014” |
Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
Ενδείξεις | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
Αντενδείξεις | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
Στειρότητα | Αποστειρωμένο (οξείδιο του αιθυλενίου) |
Εφάπαξ χρήση | Ναι |
Διάρκεια ζωής | 2–3 years (depending on final packaging and polymer, if any) |
Θερμοκρασία λειτουργίας | Recommended 15–25 °C for storage |
Λεπτομερής παραγγελία βάσει μεγέθους & κωδικοί προϊόντων
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Κωδικός προϊόντος |
2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
Σχετικά προϊόντα
-
Καθετήρας επέκτασης GuideX
Διαβάστε περισσότεραΈνα επέκταση ή "μητέρας και παιδιού" προσφέροντας καθετήρα ενισχυμένη υποστήριξη και reach μέσα σε δαιδαλώδη ή distal στεφανιαία/περιφερικά τμήματα, επιτρέποντας τη σταθερή πλοήγηση της συσκευής.
-
Atlas Ενδοαγγειακό περιφερικό μόσχευμα στεντ
Διαβάστε περισσότεραA καλυμμένο περιφερικό stent προσφορά μοσχεύματος ασφαλές απόφραξη ανευρυσμάτων ή αποφρακτικών βλαβών σε λαγόνιος ή μηριαίο τμημάτων, μειώνοντας τον κίνδυνο ρήξης ή επανέκφραξης.
-
Σύστημα αφαίρεσης μολύβδου LASER Hero
Διαβάστε περισσότεραA με βάση το λέιζερ συσκευή εξαγωγής που επιτρέπει ακριβές και ασφαλές αφαίρεση των καρδιακές απαγωγές (βηματοδότης ή ICD) σε περιπτώσεις λοίμωξης, δυσλειτουργίας των καλωδίων ή αναβαθμίσεων.
-
InWIRE Οδηγό σύρμα CTO 0,014" & 0,018"
Διαβάστε περισσότεραΜια σειρά από υψηλών επιδόσεων οδηγά σύρματα που προσφέρουν ανθεκτικό νιτινόλη ή ανοξείδωτο πυρήνες, υδρόφιλες επιστρώσεις και πολλαπλά σχήματα άκρων για τη διέλευση αποσαθρωμένο ή σύνθετο στεφανιαίες και περιφερικές βλάβες.