Atlas Σύστημα στεφανιαίων στελεχών από ανοξείδωτο χάλυβα
A ανοξείδωτο ατσάλι προσφορά στεφανιαίων stent στιβαρό δομική ακεραιότητα και εύκολο δυνατότητα παράδοσης για διαδερμικές στεφανιαίες επεμβάσεις ρουτίνας (PCI), εξισορροπώντας την αποδοτικότητα κόστους με την αξιόπιστη απόδοση.
Το ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Γενικές προδιαγραφές προϊόντος
Προδιαγραφές | Λεπτομέρεια / Αξία |
Όνομα προϊόντος | Atlas Coronary Stent (Stainless Steel) |
Stent Type | Balloon-Expandable Coronary Stent |
Υλικό | 316L Stainless Steel (Medical Grade) |
Strut Thickness | ~100 μm (typical) |
Σχεδιασμός | Open-Cell or Hybrid-Cell design (varies by specific model) |
Nominal Pressure (NP) | ~8–9 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Σύστημα παράδοσης | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Συμβατότητα οδηγού σύρματος | 0.014” |
Ενδείξεις | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
Αντενδείξεις | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
Στειρότητα | Αποστειρωμένο (οξείδιο του αιθυλενίου) |
Εφάπαξ χρήση | Ναι |
Διάρκεια ζωής | 2–3 years (based on final packaging and coating, if any) |
Θερμοκρασία λειτουργίας | Recommended 15–25 °C for storage |
Λεπτομερής παραγγελία βάσει μεγέθους & κωδικοί προϊόντων
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Κωδικός προϊόντος |
2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Σχετικά προϊόντα
-
Σύστημα μηχανικής αφαίρεσης μολύβδου Hero
Διαβάστε περισσότεραA μηχανικό εναλλακτική λύση για εξαγωγή μολύβδου, χρησιμοποιώντας εξειδικευμένα στυλεά κλειδώματος ή θήκες για να αποσπάσει ινωτικές προσκολλήσεις, εξασφαλίζοντας σταθερή έλξη για ασφαλή αφαίρεση.
-
Lotus Μικροκαθετήρας PTCA μονού αυλού & διπλού αυλού (RX)
Διαβάστε περισσότεραΜικροκαθετήρες σχεδιασμένο για στεφανιαία ή περιφερική διάβαση βλάβης, προσφέροντας διαμορφώσεις ενός ή δύο αυλών για ανταλλαγή οδηγού σύρματος, ένεση σκιαγραφικού, ή υποεπιλεκτική πρόσβαση σε βλάβες.
-
Atlas Ενδοαγγειακό περιφερικό μόσχευμα στεντ
Διαβάστε περισσότεραA καλυμμένο περιφερικό stent προσφορά μοσχεύματος ασφαλές απόφραξη ανευρυσμάτων ή αποφρακτικών βλαβών σε λαγόνιος ή μηριαίο τμημάτων, μειώνοντας τον κίνδυνο ρήξης ή επανέκφραξης.
-
Συσκευή κλεισίματος AngioTEN
Διαβάστε περισσότεραA διαδερμική σύστημα αγγειακής σύγκλεισης για αρτηριακή ή φλεβική τοποθεσίες πρόσβασης, επιτρέποντας ασφαλές αιμόσταση μετά από καθετηριασμό ή επεμβατικές διαδικασίες.