HyperClear: Laserløsning til godartet prostatahyperplasi
Et avanceret lasersystem designet til at behandle godartet prostatahyperplasi (BPH) med præcision, hvilket giver effektiv fjernelse af væv, forbedret urinflow og minimal nedetid for forbedrede patientresultater.
HyperClear represents an innovative laser therapy system designed to effectively remove surplus prostatic tissue in benign prostatic hyperplasia (BPH). Leveraging the LIFE (Laser-Induced Fiber Enucleation) method, HyperClear applies precise laser energy via a flexible fiber placed transurethrally to the obstructive zone, ablating the excess prostate tissue responsible for lower urinary tract symptoms (LUTS). This approach may be performed outpatient—often with local anesthesia—enhancing patient comfort while maintaining efficacy and safety.
High-Precision Laser Fiber
- Optimized Energy Delivery: The laser fiber is advanced through the urethra to the blocked area, targeting surplus prostate tissue while minimizing collateral damage.
- LIFE Method: Focused on selective tissue vaporization or enucleation, ensuring clean resection planes and predictable tissue removal.
Outpatient Feasibility
- Local Anesthesia: Allows many patients to undergo the procedure without the risks or recovery times associated with general anesthesia.
- Rapid Recovery: Less invasive than conventional transurethral resections, potentially reducing hospital stays and improving patient throughput.
Real-Time Visualization
- Precise Tissue Identification: Endoscopic imaging guides the laser fiber to the obstructive tissue, ensuring thorough clearance of the prostatic urethra.
- Controlled Ablation: The surgeon can finely tune laser energy to match the tissue’s vascularity and density, limiting the risk of deep thermal damage.
Efficient & Gentle Tissue Removal
- Targeted Laser Ablation: Precisely removes hyperplastic prostate segments that hinder urine flow, preserving healthy tissue zones.
- Hemostatic Effect: Laser energy also cauterizes small vessels during tissue vaporization, reducing intraoperative bleeding.
Kliniske fordele og anvendelser
Benign Prostatic Hyperplasia (BPH)
- Symptomatic Relief: Alleviates classic LUTS such as frequent urination, weak urine stream, and prolonged emptying times.
- Patient Selection: Suited for patients with moderate-to-severe BPH who seek a less invasive alternative to standard TURP or open prostatectomy.
Minimal Invasiveness
- Outpatient Possibility: Potentially performed under local anesthesia, minimizing hospitalization and facilitating early mobilization.
- Lower Bleeding Risk: Laser-based enucleation or vaporization significantly reduces hemorrhage compared to mechanical resection methods.
Enhanced Patient Experience
- Shorter Convalescence: Many patients resume daily activities sooner, with less postoperative discomfort or catheterization durations.
- Reduced Need for General Anesthesia: Local or spinal anesthesia lessens systemic risks, beneficial for older or comorbid patients.
Technical Specifications
Specifikation | Detalje / værdi |
Produktets navn | CytroFIX® Superior Clavicula Plates |
Materiale | High-Purity Titanium Alloy (e.g., Ti-6Al-4V ELI) |
Plate Profile | Low-profile, contoured for superior clavicle placement |
Locking Mechanism | Locking or non-locking titanium screws; optional variable-angle locking |
Screw Diameter | 2.7 mm or 3.5 mm (titanium cortical screws, depending on hole specification) |
Plate Thickness | ~2.0–2.5 mm (minimized profile) |
Hole Array | Multiple holes for bridging, compression, or combined fixation patterns |
Radiopacitet | Titanium visible on fluoroscopy (optional etched markers) |
Sterilitet | Provided non-sterile (autoclavable) or sterile, single use or reusable instrumentation (verify product line) |
Holdbarhed | Indefinite if stored properly; reusable within recommended inspection cycles |
Kliniske indikationer | Midshaft/lateral clavicle fractures requiring superior plating, osteotomies, nonunion correction |
Regulatory Compliance | Conforms to ISO 13485, CE/FDA (region-specific), meets orthopedic implant standards |
Size & Ordering Matrix
Plate Length (mm) | Hole Count | Curvature | Compatible Screw | Produktkode | Noter |
60 | 4 | Mild Superior Bend | 2.7 mm Locking/Non-Locking | CFX-SCL-60-4-27-Ti | Shorter plate for smaller fractures in lateral or mid-shaft |
70 | 5 | Mild Superior Bend | 2.7 mm Locking/Non-Locking | CFX-SCL-70-5-27-Ti | Extended coverage for mild to moderate fractures |
80 | 5 | Moderate Superior Bend | 2.7 or 3.5 mm Locking | CFX-SCL-80-5-MX-Ti | Bridges midshaft fractures with variable-angle options |
90 | 6 | Moderate Superior Bend | 3.5 mm Locking/Non-Locking | CFX-SCL-90-6-35-Ti | For larger or multi-fragment fractures requiring robust support |
100 | 7 | Enhanced Superior Contour | 3.5 mm Locking/Non-Locking | CFX-SCL-100-7-35-Ti | Accommodates more complex or extended fracture lines |
110 | 8 | Enhanced Superior Contour | 3.5 mm Locking/Non-Locking | CFX-SCL-110-8-35-Ti | Longest plate design for challenging multi-segment fractures |
Relaterede varer
-
FlexInject Fleksibel injektionsnål
Læs mereDenne fleksible nål er designet til præcision og brugervenlighed og sikrer præcis levering af terapeutiske midler under urologiske procedurer, hvilket giver forbedret manøvredygtighed og patientkomfort.
-
Pelvion Pyeloplastik-kateter
Læs mereDette kateter er specielt designet til pyeloplastikprocedurer og sikrer optimal dræning og støtte af nyrebækkenet, hvilket fremmer effektiv heling og forbedret urinflow efter operationen.
-
HyperTiss Intrakavitært hypotermi-sæt til behandling af blærekræft
Læs mereEt avanceret medicinsk system, der er designet til at levere kontrolleret hypotermi direkte til blærehulen, hvilket forbedrer de terapeutiske resultater ved behandling af blærekræft ved at øge tumorfølsomheden over for kemoterapi og reducere antallet af tilbagefald.
-
Atlas koronar stentgraft-system
Læs mereA dækket koronar stent system, der leverer ekstraluminal forsegling i Perforeringer eller pseudoaneurismerDet opretholder koronar åbenhed, mens det forhindrer ekstravasation.