Dolphin Sub-Intimal Entry Catheter
A sub-intimal entry system aiding re-entry into the true lumen after sub-intimal crossing in CTO or heavily occluded segments, ensuring minimal dissection expansions.
The Dolphin Sub-Intimal Entry Catheter, by Invamed—a global medical device manufacturer—is uniquely designed to assist in subintimal dissection and re-entry in chronic total occlusions (CTOs) or heavily diseased vascular segments. By providing a targeted pathway to the subintimal space and then guiding re-entry into the true lumen, Dolphin enhances procedural success in complex peripheral or coronary interventions.
Dedicated Subintimal Navigation
Engineered tip or “needle” design helps negotiate the subintimal plane, enabling operators to bypass occlusive lesions.
True Lumen Re-Entry
Specialized distal tip geometry assists in precision re-entry to the true lumen, improving success rates in otherwise intractable CTOs.
High Pushability & Torque
Braided or coiled shaft construction delivers robust force transmission for crossing tough plaque or calcifications.
Hydrophilic Coating (optional)
Minimizes friction against vessel walls, reducing dissection risk and procedural time in challenging anatomies.
Wide Clinical Utility
Indicated for peripheral artery disease (PAD) with occlusive lesions, especially superficial femoral or popliteal arteries. May also be adapted for select coronary interventions.
Kontraindikationer
Extremely tortuous vessels, advanced dissection risk, or patient conditions that preclude subintimal techniques.
Generelle produktspecifikationer
Specifikation | Detalje / værdi |
Produktets navn | Dolphin Sub-Intimal Entry Catheter |
Tilsigtet brug | Facilitates subintimal dissection and re-entry in chronic total occlusion (CTO) or heavily diseased vessels (peripheral or coronary) |
Design af kateter | Specially shaped distal tip or “re-entry” needle to access the true lumen from a subintimal plane |
Materiale | Pebax/Polyamide shaft with braided reinforcement, possible radiopaque or tungsten tip |
Outer Diameter (Fr) | ~2.0–3.5 Fr for coronary or ~3.5–4.5 Fr for peripheral usage (adjust as appropriate) |
Indre lumen | Typically 0.014” guidewire compatibility |
Arbejdslængde | ~80–150 cm (varies by product code) |
Tip-konfiguration | Tapered, angled, or “needle” re-entry tip, radiopaque marker for precise subintimal guidance |
Marker Bands | 1–2 near the distal segment for fluoroscopic visualization |
Sheath Compatibility | 4F–6F (small coronary variants), 5F–7F (peripheral variants) |
Sterilitet | Steril (ethylenoxid) |
Engangsbrug | Ja |
Holdbarhed | ~2–3 years if stored in sealed packaging at 15–25 °C |
Kliniske indikationer | Re-entering true lumen in CTOs, subintimal approach in peripheral arteries (e.g., superficial femoral), or advanced coronary CTO crossing |
Kontraindikationer | Extremely tortuous or heavily calcified vessels, known device material allergies, or situations unsuited for subintimal strategy |
Dolphin Sub-Intimal Entry Catheter
Fr Size | Arbejdslængde (cm) | Tip Style | Produktkode | Noter |
2.0 Fr | 80 | Tapered (Needle Tip) | DOL-SI-2.0-80-TP | Ultra-low profile for coronary subintimal re-entry |
2.0 Fr | 100 | Angled Needle | DOL-SI-2.0-100-AN | Slightly angled tip, moderate length |
2.3 Fr | 80 | Straight “Re-Entry” | DOL-SI-2.3-80-ST | Balanced OD for small peripheral or coronary usage |
2.3 Fr | 135 | Tapered (Needle Tip) | DOL-SI-2.3-135-TP | Extended length, deeper CTO crossing |
2.6 Fr | 100 | Angled “Re-Entry” | DOL-SI-2.6-100-AN | Mid-range OD plus angled tip for subintimal SFA approach |
2.6 Fr | 135 | Straight “Re-Entry” | DOL-SI-2.6-135-ST | Long length for complicated multi-segment occlusions |
3.0 Fr | 100 | Tapered (Needle Tip) | DOL-SI-3.0-100-TP | Slightly larger OD for peripheral subintimal re-entry |
3.0 Fr | 135 | Angled “Re-Entry” | DOL-SI-3.0-135-AN | Extended length, angled tip for advanced re-entry strategy |
3.5 Fr | 100 | Straight Needle | DOL-SI-3.5-100-ST | Larger OD for robust push in heavily calcified vessels |
3.5 Fr | 135 | Tapered (Needle Tip) | DOL-SI-3.5-135-TP | Max length for tall patients or extensive subintimal navigation |
4.0 Fr | 135 | Angled “Re-Entry” | DOL-SI-4.0-135-AN | (If your line extends to 4.0 Fr or beyond for large peripheral usage) |
Relaterede varer
-
Invaducer Intraducer
Læs mereA titanium eller legering brystbenspladesystem, der giver stiv fiksering efter midtlinje sternotomi, hvilket forbedrer brystbensstabilitet og reducere risikoen for infektion eller dehiscens efter hjertekirurgi.
-
TemREN Peripheral Atherectomy System
Læs mereA rotational eller directional atherectomy device specialized for plaque excision in peripheral arteries, augmenting lumen restoration while minimizing barotrauma.
-
Atlas Peripheral Stent System
Læs mereA robust peripheral stent platform designed for femoral, iliaceller popliteal lesions, ensuring adequate radial støtte og low restenosis rates in PAD interventions.
-
AngioTEN-lukkeanordning
Læs mereA perkutan vaskulært lukningssystem til arteriel eller venøs adgangssteder, hvilket gør det muligt sikker hæmostase efter kateterisering eller interventionelle procedurer.