Keeper Endovaskulární snare
A více smyček zařízení pro vytahování nástrah cizí těleso nebo embolus zachycení, zajištění zabezpečené zapojení a odstoupení od smlouvy z cévních lumenů.
Keeper Endovascular Snare by INVAMED is a single-use, sterile device engineered to capture and retrieve intravascular foreign objects, from dislodged stents or guidewire fragments to thrombosis and other undesirable materials in the vascular system. With an innovative loop design and low-profile catheter introduction, the Keeper Snare provides precise control, maximum radial force, and minimized trauma—streamlining procedures in both arterial and venous settings.
Flexible Snare Loop Geometry
- Constructed from high-tensile nitinol or stainless-steel wires in various loop diameters for optimal capture potential.
- Retains shape memory and radial strength even after multiple manipulation cycles, supporting consistent retrieval.
Ergonomic Catheter Delivery
- Low-profile catheter sheath simplifies femoral, radial, or brachial access.
- Catheter tip and snare loop are radiopaque, facilitating fluoroscopic or angiographic visualization and precise target approach.
Enhanced Capture and Control
- The snare loop compresses or expands under operator control, securely gripping foreign bodies or occlusive elements without risk of fragmenting them further.
- A dedicated handle or torque device (depending on model) provides precision in loop rotation and retraction.
Minimally Invasive Retrieval
- Reduces or eliminates the need for open surgical extraction, shortening patient recovery times and lowering complication risks.
- Effective for broken guidewires, catheter fragments, or other intraluminal materials that must be removed promptly to avoid embolization or vascular injury.
Broad Range of Indications
- Suitable for arterial or venous retrieval in peripheral vessels, central vasculature, or even select cardiac chambers if indicated.
- Helpful in addressing intravascular coil misplacements, filter retrievals, or spontaneous foreign body presence.
Specifikace produktu
| Specifikace | Detail / Hodnota |
| Název produktu | Keeper Endovaskulární snare |
| Zamýšlené použití | Retrieval of foreign bodies, dislodged stents, or thrombus fragments from vascular lumens |
| Snare Material | Nitinol or Stainless Steel loop with radiopaque marker |
| Loop Diameter Range | ~2–35 mm (depending on vessel size) |
| Shaft Length | 80–120 cm (various) |
| Kompatibilita vodicích drátů | 0.018” or 0.035” (check model) |
| Sheath Compatibility | 4–6F typical |
| Sterilita | Sterilní, na jedno použití |
| Doba použitelnosti | ~3 years, 15–25 °C storage |
Objednávání a velikostní matice
| Loop Diameter (mm) | Shaft Length (cm) | Guidewire Size | Kód produktu |
| 5 | 80 | 0.018" | KEE-5-80-018 |
| 10 | 80 | 0.018" | KEE-10-80-018 |
| 15 | 100 | 0.035" | KEE-15-100-035 |
| 20 | 100 | 0.035" | KEE-20-100-035 |
| 25 | 120 | 0.035" | KEE-25-120-035 |
| 35 | 120 | 0.035" | KEE-35-120-035 |
Související produkty
-

Lotus Mikrokatétr PTCA s jedním lumenem a dvojitým lumenem (RX)
Čtěte víceMikrokatétry určené pro koronární nebo křížení periferních lézí a nabízí konfigurace s jedním nebo dvěma lumeny pro výměna vodicích drátů, vstřikování kontrastunebo subselektivní přístup k lézi.
-

JaGuar Vodicí plášť
Čtěte víceA pletené vodicí plášť poskytující točivý moment kontrola a kink odolnost pro bezpečnou navigaci zařízení v periferie nebo viscerální zásahy.
-

Vodicí katétry AngioCATH
Čtěte víceVysoce výkonné vodicí katétry s optimální točivý moment reakce a přesný tip tvary pro koronární nebo periferie zákroků, což zajišťuje stabilní dodávku zařízení a jasnost zobrazení.
-

Nexus Venózní a arteriální kanyla
Čtěte víceVíceúčelový žilní a arterie podpůrné kanyly mimotělní oběh během kardiopulmonálního bypassu nebo ECMO, čímž se zajistí optimální průtoky a hemokompatibilita.