Inca® Система за защита от емболии

A катетър предоставяне на тромболитичен агенти, докато филтър защита предотвратява дисталната емболизация, като осигурява по-безопасно фармакологично разтваряне на тромбите.

Сайтът Inca® Система за защита от емболии е small, nitinol-based filtration device designed to capture embolic material released during interventional procedures in the carotid artery, lower extremity arterial segments, and other vascular sites. By offering distal protection against plaque or thrombus fragments dislodged during angioplasty, stenting, or other endovascular interventions, Inca enhances patient safety и procedure efficiency—enabling clinicians to maintain unobstructed distal flow while reducing the risk of embolic complications.

Nitinol Filtration Cage
  • Shape-Memory Alloy: The self-expanding nitinol structure conforms to vessel lumens, helping to securely capture dislodged debris and prevent distal embolization.
  • Minimal Profile: Compact, low-profile design ensures smooth insertion and целеви deployment in narrow or tortuous arteries.
  • Downstream Protection: Positioned beyond the site of intervention, Inca effectively traps microscopic or larger debris, safeguarding distal vasculature from occlusion.
  • Precise Positioning: Engineered radiopacity facilitates real-time visualization under fluoroscopy, enabling accurate filter placement.
  • User-Friendly Delivery System: Allows бързо и контролиран expansion of the filter cage at the desired location.
  • Safe Filter Retrieval: Collapses the nitinol mesh into a low-profile sheath post-procedure, retaining captured material for removal without vessel injury.
  • Carotid Interventions: Decreases stroke risk from plaque dislodgement during carotid stenting or angioplasty.
  • Peripheral Procedures: Protects lower extremity arteries from fragmented thrombus during limb revascularization.
  • Coronary Interventions (where indicated): Potentially usable to prevent distal embolization in certain coronary interventions (depending on labeling).
  • Shape-Memory Alloy: The self-expanding nitinol structure conforms to vessel lumens, helping to securely capture dislodged debris and prevent distal embolization.
  • Minimal Profile: Compact, low-profile design ensures smooth insertion and целеви deployment in narrow or tortuous arteries.
  • Downstream Protection: Positioned beyond the site of intervention, Inca effectively traps microscopic or larger debris, safeguarding distal vasculature from occlusion.
  • Precise Positioning: Engineered radiopacity facilitates real-time visualization under fluoroscopy, enabling accurate filter placement.
  • User-Friendly Delivery System: Allows бързо и контролиран expansion of the filter cage at the desired location.
  • Safe Filter Retrieval: Collapses the nitinol mesh into a low-profile sheath post-procedure, retaining captured material for removal without vessel injury.
  • Carotid Interventions: Decreases stroke risk from plaque dislodgement during carotid stenting or angioplasty.
  • Peripheral Procedures: Protects lower extremity arteries from fragmented thrombus during limb revascularization.
  • Coronary Interventions (where indicated): Potentially usable to prevent distal embolization in certain coronary interventions (depending on labeling).

Спецификации на продукта

Спецификация Подробности / стойност
Име на продукта Inca Thrombolysis Catheter with Protection Filter
Предназначение Pharmacological thrombolysis of acute or subacute thrombi in peripheral or venous systems, featuring a built-in filter to catch embolic debris
Дизайн на катетъра Multi-lumen catheter with distal infusion ports, integrated filter basket or net
Материал Pebax/Polyamide shaft, nitinol or stainless steel filter frame
Външен диаметър (F) ~4–6F (depending on infusion lumen size)
Работна дължина ~80–120 cm (varies by code)
Infusion Ports Side holes over a specified segment for uniform drug distribution
Filter Mechanism Collapsible mesh near distal tip to capture dislodged debris
Съвместимост на проводниците Typically 0.014” or 0.018”
Стерилност Стерилен, за еднократна употреба
Срок на годност ~2–3 years if stored at 15–25 °C in sealed packaging
Клинични индикации Catheter-directed thrombolysis (e.g., in DVT, peripheral arterial occlusions), preventing distal embolization
Противопоказания Excessive vessel tortuosity, large-bore clots exceeding filter capacity, known intolerance to materials

Матрица за поръчка и размер

Външен диаметър (F) Работна дължина (cm) Infusion Segment (cm) Filter Diameter (mm) Код на продукта
4F 80 10 10 INC-4F-80-10-10
4F 100 15 12 INC-4F-100-15-12
5F 80 10 14 INC-5F-80-10-14
5F 120 20 14 INC-5F-120-20-14
6F 80 15 33 INC-6F-80-15-16
6F 120 20 33 INC-6F-120-20-18