Extender Балонен катетър PTA, изпускащ лекарства
Extender Балонен катетър PTA, изпускащ лекарства; A с лекарствено покритие балон за периферна транслуминална ангиопластика (PTA), освобождавайки антипролиферативен агенти за намаляване на рестенозата във феморални или поплитеални артерии.

Elevating Angioplasty with Precision and Efficacy
- Balloon Material: Durable and flexible for precise navigation and deployment.
- Compatibility: Usable with standard catheter systems.
- Size Range: Available in various sizes to accommodate different vascular diameters.
- Compatibility: Usable with standard catheter systems.
Choose for Optimal Drug Delivery
- Deployment: Rapid and controlled balloon inflation and deflation.
- Drug Type: Paclitaxel Incorporates anti-proliferative drugs to prevent restenosis.
- Drug Coating: Homogeneous drug distribution for consistent delivery.
- Drug Type: Paclitaxel Incorporates anti-proliferative drugs to prevent restenosis.


Innovation Meets Vascular Treatment
- Highly compliant balloon material ensures optimal contact with the vessel wall foreffective drug delivery.Therapeutic window achieved after 30 seconds inflation time.Rapid drug release and absorption kinetics ensure targeted therapeutic effects,assuring physicians of sustained results.
Safety and Effectiveness of the Novel TemREN Atherectomy System Combined Use With Extender Drug-Eluting Balloon in Lower Extremity Arteries
Results
For the primary analysis, the rate of lesion technical success was 97.0%, meeting the prospectively established target performance goal of 86%. After postatherectomy adjunctive therapy, residual stenosis was 30% for 100% of lesions means final diameter stenosis, 10.9%.
Early and midterm results of the retrograde transpopliteal approach as the first-line treatment for total occlusions of iliofemoral arteries.
Results
Technical success, defined as restored patency with no stenosis greater than 30%, was achieved in (92.9%) of patients. A patient who was a heavy smoker showed acute symptoms of claudication due to 80% stenosis of the iliac stent 20 days after discharge and was treated with balloon angioplasty.
- 3.0-3.5ug / mm2 drug dosage
- <2mm particles
- Contrast media as a drug carrier
- Minimum drug release during delivery
- Available in Non-Compliant version
- <90% drug transfer to the target lession
- Quick deflation time
- Excellent pushability
Общи спецификации на продукта
Спецификация Подробности / стойност Име на продукта Extender Drug PTA Balloon Catheter (Paclitaxel- or Sirolimus-coated, depending on your actual platform) Предназначение Percutaneous transluminal angioplasty (PTA) in peripheral arteries (e.g., femoral, popliteal, tibial) to reduce restenosis Balloon Material Semi-/Non-Compliant polymer (Nylon, Pebax) with drug coating Drug Coating Paclitaxel or alternative antiproliferative agent (x µg/mm²) Nominal Inflation Pressure ~6–10 atm (depends on diameter) Rated Burst Pressure (RBP) ~12–16 atm (depending on balloon size) Catheter Shaft Length Typically 80–150 cm (adjust for your product line) Съвместимост на проводниците 0.018” or 0.035” (commonly for peripheral balloons—verify actual design) Coating Release Rapid drug release upon inflation (~30–60 seconds recommended inflation time) Стерилност Стерилни (етиленов оксид) Еднократна употреба Да Срок на годност 2–3 years if stored at 15–25 °C in sealed packaging Клинични индикации PAD (peripheral artery disease), femoropopliteal lesions, below-the-knee disease, in-stent restenosis in peripheral arteries Противопоказания Highly calcified lesions requiring atherectomy first, allergic reaction to drug coating, severely tortuous or occluded vessels Diameter Range 1.5–6.0 mm (For smaller vessels, BTK or moderate femoral)
Balloon Dia (mm) Balloon Length (mm) Nominal Pressure (atm) RBP (atm) Drug Load (μg) Код на продукта 1.5 20 6 12 ~200 EXD-PTA-1.5x20 1.5 40 6 12 ~400 EXD-PTA-1.5x40 2.0 40 7 14 ~600 EXD-PTA-2.0x40 2.0 60 7 14 ~900 EXD-PTA-2.0x60 2.5 80 8 14 ~1200 EXD-PTA-2.5x80 3.0 80 8 14 ~1500 EXD-PTA-3.0x80 3.0 100 8 14 ~1900 EXD-PTA-3.0x100 3.5 100 8 14 ~2200 EXD-PTA-3.5x100 4.0 100 9 16 ~2500 EXD-PTA-4.0x100 4.0 120 9 16 ~3000 EXD-PTA-4.0x120 4.5 120 9 16 ~3400 EXD-PTA-4.5x120 5.0 80 9 16 ~2000 EXD-PTA-5.0x80 5.0 120 9 16 ~3000 EXD-PTA-5.0x120 6.0 80 10 16 ~2200 EXD-PTA-6.0x80 6.0 120 10 16 ~3300 EXD-PTA-6.0x120 Diameter Range 7.0–12.0 mm (For bigger femoral/popliteal or iliac arteries)
Balloon Dia (mm) Balloon Length (mm) Nominal Pressure (atm) RBP (atm) Drug Load (μg) Код на продукта 7.0 60 8 14 ~2000 EXD-PTA-7.0x60 7.0 80 8 14 ~2600 EXD-PTA-7.0x80 7.0 120 9 16 ~3900 EXD-PTA-7.0x120 8.0 80 9 16 ~3000 EXD-PTA-8.0x80 8.0 120 9 16 ~4500 EXD-PTA-8.0x120 9.0 80 9 16 ~3400 EXD-PTA-9.0x80 9.0 120 9 16 ~5100 EXD-PTA-9.0x120 10.0 80 10 16 ~3800 EXD-PTA-10.0x80 10.0 120 10 16 ~5700 EXD-PTA-10.0x120 12.0 80 10 16 ~4600 EXD-PTA-12.0x80 12.0 120 10 16 ~6900 EXD-PTA-12.0x120 Paclitaxel-Iopromid Coating- Optimal Drug Delivery: Rapid paclitaxel release into the vessel wall upon balloon inflation aids in inhibiting neointimal hyperplasia.
- Stable Surface Layer: The specialized coating formulation resists delamination, ensuring controlled, uniform distribution of the antiproliferative agent.
Wide Balloon Diameter & Length Range- Diameter: 1.5 mm–12.0 mm covers small distal arteries up to larger peripheral segments.
- Length: 20 mm–220 mm addresses both short, focal lesions and extensive diseased vessel segments—reducing procedural device exchanges.
Low-Profile Catheter & Multiple Guidewire Compatibility- 5F Shaft Design: Minimizes access-site trauma, beneficial for challenging anatomies or smaller access routes.
- Guidewire Options: Accommodates 0.014”, 0.018”, or 0.035” wires, offering flexibility in diverse peripheral vascular lesions.
High Radiopacity for Accurate Placement- Pt-Ir Markers: Ensures clear, real-time balloon positioning under fluoroscopy, facilitating precise lesion coverage and drug deposition.
Varied Catheter Lengths- 80, 90, 120, 135, 150 cm: Multiple workable lengths allow operators to select the ideal configuration for femoral, popliteal, tibial, or other target vessels.
Свързани продукти
-
Устройство за затваряне AngioTEN
ОщеA перкутанно система за затваряне на кръвоносни съдове артериален или венозен сайтове за достъп, което позволява защитен хемостаза след катетеризация или интервенционални процедури.
-
Viper™ Valved Infusion Catheters
ОщеСайтът Viper™ Valved Infusion Catheter е single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with или without a guidewire in place.
-
TemREN PRO Atherectomy System
ОщеTemREN PRO Atherectomy System; A ротация или насочване устройство за атеректомия, специализирано за изрязване на плака в периферните артерии, увеличавайки лумен възстановяване, като същевременно се свежда до минимум баротравмата.
-
JaGuar Водеща обвивка
ОщеA оплетени водеща обвивка, осигуряваща въртящ момент контрол и изкривяване устойчивост за сигурна навигация на устройствата в периферни устройства или висцерален интервенции.
















































































Контакти и поддръжка
Как можем да помогнем?
Преди да започнем, какво ви описва най-добре?
Контакти и поддръжка
Специалисти в областта на здравеопазването
Онлайн формуляр за запитване
За общи или свързани с продукта въпроси попълнете нашия бърз онлайн формуляр. Ще получите потвърждение и референтен номер за проследяване.
Запитвания за продукти
Клинична и изследователска подкрепа
Обучение и образование
Техническа поддръжка
Контакти и поддръжка
Пациент и лица, полагащи грижи
Онлайн формуляр за запитване
За общи или свързани с продукта въпроси попълнете нашия бърз онлайн формуляр. Ще получите потвърждение и референтен номер за проследяване.
Употреба на продукта и безопасност
Поръчка и плащане
Подкрепа и последващи грижи
Контакти и поддръжка
Доставчици и дистрибутори
Онлайн формуляр за запитване
За общи или свързани с продукта въпроси попълнете нашия бърз онлайн формуляр. Ще получите потвърждение и референтен номер за проследяване.
Партньорство и договор
Логистика и доставка
Съответствие и документация
Контакти и поддръжка
Доставчици и дистрибутори
Онлайн формуляр за запитване
За общи или свързани с продукта въпроси попълнете нашия бърз онлайн формуляр. Ще получите потвърждение и референтен номер за проследяване.
Съобщения за пресата и новини
Интервюта и изявления
Събития и конференции
Контакти и поддръжка
Други / Общи запитвания
Онлайн формуляр за запитване
За общи или свързани с продукта въпроси попълнете нашия бърз онлайн формуляр. Ще получите потвърждение и референтен номер за проследяване.
Обща информация
Отзиви и предложения
Линия за поддръжка на HeadQuarter
- One World Trade Center, 285 Fulton Street. Ню Йорк, NY 10007, САЩ
- globalsales@invamed.com
- +1 (347) 535-0630