Stena kəllədaxili çox qatlı axın modulatoru

A çoxqatlı üçün axını yönləndirən konstruksiya kəllədaxili anevrizmalar, əsas budaq perfuziyasını qoruyarkən qan axını anevrizma kisəsindən uzağa yönləndirir.

The Stent Neurovascular Multilayer Flow Modulator a multi-layer, self-expandable implant designed to redirect blood flow across intracranial aneurysms or pseudoaneurysms (saccular, fusiform, or dissection). Constructed from nitinol braided wires, this flow-guided device harnesses hemodynamic modulation to promote stable aneurysm occlusion while preserving key vessel branches.

Multi-Layer Braided Nitinol Wires
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring dəqiq navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring dəqiq navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.

Məhsulun spesifikasiyası

Spesifikasiya Detal / Dəyər
Məhsulun adı Stena kəllədaxili çox qatlı axın modulatoru
Nəzərdə tutulan istifadə Endovascular flow diversion for intracranial aneurysms (saccular, fusiform) or complex neurovascular lesions
Dizayn Multi-layer braided nitinol mesh stent, self-expanding, designed to modulate blood flow while preserving side branches
Material Medical-grade Nitinol (Nickel-Titanium)
Yerləşdirmə Mexanizmi Sheath-based retraction or microcatheter system release
Delivery Catheter Compatibility Typically 0.027” or 0.021” ID microcatheter (depending on stent diameter)
Radiopaq markerlər Proximal and distal marker bands for fluoroscopic positioning
MR Uyğunluğu MR Conditional (verify labeling)
Sterillik Steril, tək istifadə
Raf Ömrü ~3–5 years, stored at 15–25 °C in sealed packaging
Klinik göstərişlər Intracranial aneurysms (small or large/giant), dissecting or fusiform aneurysms, flow diversion in distal vessels
Əks göstərişlər Extremely tortuous intracranial vessels beyond feasible access, known nickel allergy, insufficient landing zone

Sifariş və Ölçü Matrisi

Stent Diameter (mm) Stent Length (mm) Microcatheter ID (inch) Məhsul Kodu Qeydlər
2.5 12 0,021” STN-IC-2.5x12-021 Smaller diameter, short aneurysm coverage
2.5 18 0,021” STN-IC-2.5x18-021 Extended length for multiple side branches
3.0 18 0,027” STN-IC-3.0x18-027 Common diameter for medium intracranial vessels
3.0 25 0,027” STN-IC-3.0x25-027 Longer stent for extended aneurysm neck
3.5 20 0,027” STN-IC-3.5x20-027 Slightly larger diameter for wide-neck aneurysms
3.5 30 0,027” STN-IC-3.5x30-027 Extended coverage in more proximal segments
4.0 20 0,027” STN-IC-4.0x20-027 Larger diameter for cavernous ICA aneurysms
4.0 30 0,027” STN-IC-4.0x30-027 Extended length for giant aneurysm coverage
4.5 25 0,027” STN-IC-4.5x25-027 XL diameter for large internal carotid segments
4.5 35 0,027” STN-IC-4.5x35-027 Maximum coverage for fusiform or dissecting lesions