نظام استئصال الدوالي الوريدية بالترددات الراديوية ThermoBLOCK

A الترددات الراديوية منصة الاستئصال لـ غير كفء الأوردة السطحية التي تقدم حراري إغلاق الوريد الصافن أو الأوردة المثقبة لتخفيف الدوالي الأعراض.

إن Thermal Coagulation RF Ablation Generator هو متقدم, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy إلى ThermoBLOCK™ catheters و ThermoBLOCK™ stylets—enabling المستهدفة thermal ablation for chronic venous insufficiency (CVI). Equipped with a في الوقت الفعلي monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring آمنة و consistent power application while protecting surrounding tissues.

Real-Time Feedback Control
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing و sealing of incompetent veins.
  • الحد الأدنى من الأضرار الجانبية: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing و sealing of incompetent veins.
  • الحد الأدنى من الأضرار الجانبية: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.

مواصفات المنتج

المواصفات التفاصيل / القيمة
اسم المنتج ThermoBLOCK Varicose Vein RF Ablation System
الاستخدام المقصود Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins
RF Catheter Design 6–7F catheter with electrode segment near distal tip, temperature-controlled
Nominal Power ~10–30 W (depends on vein diameter and system setting)
طول القسطرة ~60–120 cm (varies by code)
Generator Compatibility ThermoBLOCK RF Generator or universal 460 kHz system
Temperature Monitoring Integrated thermocouple in ablation segment
Treatment Cycle Typically ~20–40 seconds per segment, auto-regulated by temperature feedback
العقم معقم، للاستخدام مرة واحدة
مدة الصلاحية ~2–3 years at 15–25 °C
المؤشرات السريرية Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence
موانع الاستعمال Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials

مصفوفة الترتيب والحجم

حجم القسطرة (F) طول القسطرة (سم) Ablation Segment (cm) رمز المنتج الملاحظات
6F 60 7 TBLK-6F-60-7 Short catheter for small segments
6F 100 7 TBLK-6F-100-7 Standard ablation length, extended shaft
7F 100 10 TBLK-7F-100-10 Longer ablation segment for large GSV trunk
7F 120 10 TBLK-7F-120-10 For taller patients or more extensive reflux
7F 120 15 TBLK-7F-120-15 Extra ablation segment for major trunk veins