Dolphin Dolphin ZEBRA قسطرة دعم العبور
متخصصون ZEBRA-نمط ZEBRA تحسين قسطرة الدعم المغلفة الرؤية تحت التنظير الفلوري، مما يتيح عبور الآفة بشكل متسق في معقد الانسدادات.
The Dolphin® Zebra Crossing Catheter, presented by Invamed is a specialized crossing support catheter distinguished by its striped “zebra” pattern and high-flex design. Developed to facilitate guidewire crossing through complex or chronic total occlusion (CTO) lesions, the Zebra pattern on the shaft enhances fluoroscopic visibility, ensuring improved lesion access and precise guidewire support in challenging peripheral or coronary interventions.
Zebra Striping for Enhanced Visibility
- The catheter shaft features a distinctive striped pattern, boosting contrast under fluoroscopy and aiding real-time positional awareness in tortuous or occlusive vessels.
High Pushability & Torque
- Braided or coiled shaft architecture delivers robust torque response, critical for navigating complex plaque or calcific lesions.
Low-Friction Coating (Optional)
- Minimizes vessel resistance, promoting seamless advancement in subintimal or heavily diseased segments.
Versatile Clinical Utility
- Suitable for peripheral artery disease (PAD) and complex coronary CTO crossing, offering a stable support platform for balloon/stent delivery devices.
المواصفات العامة للمنتج
المواصفات | التفاصيل / القيمة |
اسم المنتج | Dolphin Dolphin ZEBRA قسطرة دعم العبور |
الاستخدام المقصود | Facilitates guidewire crossing in complex, calcified, or tortuous peripheral and/or coronary lesions; enhanced visibility with distinct Zebra pattern |
تصميم القسطرة | Braided shaft for pushability and torque control, featuring a striped (Zebra) pattern for improved fluoroscopic visibility |
المواد | Pebax/Polyamide with stainless steel or nitinol reinforcement, potential hydrophilic coating on distal segment |
نطاق القطر الخارجي | ~2.0–3.0 Fr for coronary use; ~3.5–4.5 Fr for peripheral usage (adjust per your actual product line) |
التجويف الداخلي | Typically 0.014” guidewire compatibility |
طول العمل | ~80–150 cm (depending on model) |
تكوين النصيحة | Straight or angled tip, radiopaque marker(s) near the distal end |
Marker Bands | 1–2 bands, plus the Zebra pattern shaft for enhanced fluoroscopic tracking |
توافق الغلاف | 4F–6F (coronary variants), 5F–7F (peripheral variants), verify your product designs |
العقم | معقم (أكسيد الإيثيلين) |
استخدام واحد | نعم |
مدة الصلاحية | ~2–3 years if stored in sealed packaging at 15–25 °C |
المؤشرات السريرية | CTO crossing, tortuous segment navigation, advanced lesion crossing in both coronary and peripheral vasculature |
موانع الاستعمال | Extremely tight or highly angulated vessels, known device material hypersensitivity |
Dolphin ZEBRA
Fr Size | طول العمل (سم) | Tip Style | رمز المنتج | الملاحظات |
2.0 Fr | 80 | Straight | DOL-Z-2.0-80-ST | Ultra-low OD, short for distal coronary or small vessels |
2.0 Fr | 100 | Angled | DOL-Z-2.0-100-AN | Slight angle for crossing side branches or CTO caps |
2.3 Fr | 80 | Tapered | DOL-Z-2.3-80-TP | Tapered tip, moderate length, improved crossing in tight lesions |
2.3 Fr | 135 | Straight | DOL-Z-2.3-135-ST | Longer length for deeper coronary or tibial approach |
2.6 Fr | 100 | Angled | DOL-Z-2.6-100-AN | Balanced OD for peripheral SFA crossing or complex coronaries |
2.6 Fr | 135 | Tapered | DOL-Z-2.6-135-TP | Extended length + tapered tip for advanced subintimal cases |
3.0 Fr | 100 | Straight | DOL-Z-3.0-100-ST | Common size for moderate peripheral usage |
3.0 Fr | 135 | Angled | DOL-Z-3.0-135-AN | Additional length + angled tip for branching vessel approach |
3.0 Fr | 150 | Tapered | DOL-Z-3.0-150-TP | Max length, advanced crossing in extensive occlusions |
3.5 Fr | 135 | Straight | DOL-Z-3.5-135-ST | Larger OD, stable push, midrange length |
3.5 Fr | 150 | Tapered | DOL-Z-3.5-150-TP | Tapered tip for subintimal or collaterals |
4.0 Fr | 135 | Angled | DOL-Z-4.0-135-AN | Additional push for bigger peripheral arteries |
4.0 Fr | 150 | Straight | DOL-Z-4.0-150-ST | Extended length, largest OD for challenging SFA/iliac CTOs |
منتجات ذات صلة
-
Extender قسطرة بالون القسطرة القسطرة التاجية القسطرة القسطرية المبطنة بالمخدر باكليتاكسيل
قراءة المزيدA باكليتاكسيل المغطى بالباكليتاكسيل قسطرة البالون التاجي التي تستهدف الحد من تضيق الأوعية الدموية أثناء إجراء عملية رأب الأوعية التاجية عن طريق الجلد (PTCA)، مما يضمن توصيل الدواء بفعالية إلى جدار الوعاء الدموي.
-
ATLAS نظام دعامة الشريان التاجي المبطنة بالعقاقير ATLAS الكوبالت كروم
قراءة المزيدA الكوبالت والكروم توصيل الدعامة التاجية قوة شعاعية متينة و إمكانية تتبع ممتازةمناسبة لـ معقد أو متكلس الآفات التاجية مع ضمان الحد الأدنى من الارتداد.
-
نظام الدعامة التاجية Atlas من الفولاذ المقاوم للصدأ
قراءة المزيدA الفولاذ المقاوم للصدأ عرض الدعامات التاجية قوي السلامة الهيكلية و سهولة قابلية التسليم للتدخلات التاجية الروتينية عن طريق الجلد (PCI)، مع تحقيق التوازن بين كفاءة التكلفة والأداء الموثوق به.
-
طعم الدعامة المحيطية الطرفية Atlas داخل الأوعية الدموية
قراءة المزيدA دعامة محيطية مغطاة عرض الكسب غير المشروع آمن انسداد تمدد الأوعية الدموية أو الآفات الانسدادية في الحرقفي أو الفخذ الأجزاء، مما يقلل من خطر التمزق أو إعادة الانغلاق.