AngioHAND Clot Removal Catheter

A hand-manipulated mechanical aspiration device enabling immediate clot extraction through a manual vacuum approach, simplifying acute thrombectomy procedures.

The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.

Braided Balloon-Shaped Capture
  • Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
  • Ensures robust clot entrapment without excessive fragmentation or distal embolization.
  • Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
  • Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
  • Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
  • One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
  • Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
  • Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
  • Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
  • Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
  • Use in emergent or elective procedures where fast mechanical clot extraction is paramount.

مواصفات المنتج

المواصفات التفاصيل / القيمة
اسم المنتج AngioHAND Clot Removal Catheter
الاستخدام المقصود Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels
تصميم القسطرة Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip
نطاق القطر الخارجي ~5F–7F (depending on model)
Lumen Inner Diameter Large bore optimized for clot aspiration
طول العمل ~80–120 cm (varies by product code)
تكوين النصيحة Tapered or funnel-shaped tip to facilitate clot ingress
Radiopaque Marker Distal marker band for fluoroscopic location
Vacuum Mechanism Manual hand-syringe or integrated vacuum lock (no external pump required)
العقم معقم، للاستخدام مرة واحدة
مدة الصلاحية ~2–3 years at 15–25 °C
المؤشرات السريرية Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts
موانع الاستعمال Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy

مصفوفة الترتيب والحجم

القطر الخارجي (F) طول العمل (سم) Tip Style رمز المنتج الملاحظات
5F 80 Tapered Soft Tip ANG-HND-5F-80-TS Smaller diameter for coronary or distal peripheral
5F 100 Funnel Tip ANG-HND-5F-100-FN Moderate length, manual vacuum approach
6F 80 Tapered Soft Tip ANG-HND-6F-80-TS Common size for peripheral thrombus aspiration
6F 120 Funnel Tip ANG-HND-6F-120-FN Extended length for deeper occlusion sites
7F 100 Tapered Soft Tip ANG-HND-7F-100-TS Larger lumen for heavier clot burden
7F 120 Funnel Tip ANG-HND-7F-120-FN Maximum length plus funnel design for wide clot removal