"(《世界人权宣言》) Thermal Coagulation RF Ablation Generator 是一个 高级, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy to ThermoBLOCK™ catheters 和 ThermoBLOCK™ stylets—enabling 被定为攻击目标 thermal ablation for chronic venous insufficiency (CVI). Equipped with a 实时 monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring 安全的 和 consistent power application while protecting surrounding tissues.
Real-Time Feedback Control
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
Precision RF Delivery
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing 和 sealing of incompetent veins.
- 将附带损害降至最低: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
用户友好界面
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
Versatile Integration
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing 和 sealing of incompetent veins.
- 将附带损害降至最低: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
产品规格
规格 | 细节/价值 |
产品名称 | ThermoBLOCK Varicose Vein RF Ablation System |
预期用途 | Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins |
RF Catheter Design | 6–7F catheter with electrode segment near distal tip, temperature-controlled |
Nominal Power | ~10–30 W (depends on vein diameter and system setting) |
Catheter Length | ~60–120 cm (varies by code) |
Generator Compatibility | ThermoBLOCK RF Generator or universal 460 kHz system |
Temperature Monitoring | Integrated thermocouple in ablation segment |
Treatment Cycle | Typically ~20–40 seconds per segment, auto-regulated by temperature feedback |
无菌 | 无菌,一次性使用 |
保质期 | ~2–3 years at 15–25 °C |
临床适应症 | Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence |
禁忌症 | Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials |
订购和尺寸表
Catheter Size (F) | Catheter Length (cm) | Ablation Segment (cm) | 产品代码 | 说明 |
6F | 60 | 7 | TBLK-6F-60-7 | Short catheter for small segments |
6F | 100 | 7 | TBLK-6F-100-7 | Standard ablation length, extended shaft |
7F | 100 | 10 | TBLK-7F-100-10 | Longer ablation segment for large GSV trunk |
7F | 120 | 10 | TBLK-7F-120-10 | For taller patients or more extensive reflux |
7F | 120 | 15 | TBLK-7F-120-15 | Extra ablation segment for major trunk veins |