NeoAblate 用于软组织和肝脏的肿瘤消融探头

这种精密设计的设备专为微创肿瘤消融而设计,可提供可控能量,有效治疗软组织和肝脏肿瘤,同时最大限度地减少对周围健康组织的损伤。

NeoAblate 是一个 高级 thermal ablation system engineered for predictable, repeatable destruction of soft tissueliver tumors. By combining multi-point temperature feedback, a scalable active heating elementminimal incision demands, NeoAblate ensures 严丝合缝, 实时 monitoring of ablation zones while prioritizing patient comfortoperator workflow efficiency. With a single 18 gauge probe capable of adjustable lengths from 1–2.5 cm, NeoAblate simplifies tumor targeting in both CTMRI contexts—supporting effective, 微创 procedures.

主要功能

Predictable, Repeatable Ablations
  • Dynamic Thermal Feedback: Integrates multi-point temperature monitoring (via 1 thermocouple) for 实时 updates, enabling clinicians to fine-tune energy delivery.
  • Consistent Tissue Coagulation: Maintains a stable, uniform thermal field, helping to achieve thorough ablation margins and reduce the risk of recurrence.
  • Scalable Active Length (1–2.5 cm): The ablation zone can be adjusted to match tumor size or shape, minimizing damage to adjacent healthy tissue.
  • Slim Handle Design: Supports easy navigation and manipulation under ultrasound, CTMRI guidance, especially beneficial for complex or deep-seated lesions.
  • Beveled Surgical Tip: Aids penetration of hard tumors with minimal trauma, limiting bleeding or post-procedure discomfort.
  • Insertable Length Options:可提供 15 cm, 20 cm25 cm to accommodate varying patient body habitus and tumor locations.
  • Fits Both CT and MRI Gantries: A low-profile design ensures safe, unhindered scanning, letting operators confirm probe placement in real time.
  • Precise Localization: Facilitates accurate, image-guided ablation for improved oncological outcomes.
  • Dynamic Thermal Feedback: Integrates multi-point temperature monitoring (via 1 thermocouple) for 实时 updates, enabling clinicians to fine-tune energy delivery.
  • Consistent Tissue Coagulation: Maintains a stable, uniform thermal field, helping to achieve thorough ablation margins and reduce the risk of recurrence.
  • Scalable Active Length (1–2.5 cm): The ablation zone can be adjusted to match tumor size or shape, minimizing damage to adjacent healthy tissue.
  • Slim Handle Design: Supports easy navigation and manipulation under ultrasound, CTMRI guidance, especially beneficial for complex or deep-seated lesions.
  • Beveled Surgical Tip: Aids penetration of hard tumors with minimal trauma, limiting bleeding or post-procedure discomfort.
  • Insertable Length Options:可提供 15 cm, 20 cm25 cm to accommodate varying patient body habitus and tumor locations.
  • Fits Both CT and MRI Gantries: A low-profile design ensures safe, unhindered scanning, letting operators confirm probe placement in real time.
  • Precise Localization: Facilitates accurate, image-guided ablation for improved oncological outcomes.

临床优势与应用

Soft Tissue & Hepatic Tumors
  • Ideal for Primary & Metastatic Lesions: Ablation is effective for liver tumors or other soft tissue malignancies in subcutaneous or intramuscular sites.
  • Tissue Preservation: Focused heat confines the ablation zone around the tumor, sparing healthy parenchyma.
  • Minimal Access: A single 18 G insertion path can significantly reduce hospital stays, postoperative pain, or complications.
  • Outpatient Potential: Some smaller lesions might be managed with sedation and local anesthesia, freeing up OR time and resources.
  • Power Settings up to 40 W: Default target temperature ranges (80–110 °C) allow consistent, thorough ablation coverage.
  • Warning & Monitoring Systems: Audible and light signals alert the operator to high/low temperature or extended ablation times, ensuring immediate corrective action if needed.
  • Real-Time Temperature Feedback: Minimizes overtreatment or incomplete ablation, standardizing the ablation zone.
  • Ergonomic Stability: Slim handle and multiple insertable lengths ensure stable needle control even in challenging anatomies.
  • Ideal for Primary & Metastatic Lesions: Ablation is effective for liver tumors or other soft tissue malignancies in subcutaneous or intramuscular sites.
  • Tissue Preservation: Focused heat confines the ablation zone around the tumor, sparing healthy parenchyma.
  • Minimal Access: A single 18 G insertion path can significantly reduce hospital stays, postoperative pain, or complications.
  • Outpatient Potential: Some smaller lesions might be managed with sedation and local anesthesia, freeing up OR time and resources.
  • Power Settings up to 40 W: Default target temperature ranges (80–110 °C) allow consistent, thorough ablation coverage.
  • Warning & Monitoring Systems: Audible and light signals alert the operator to high/low temperature or extended ablation times, ensuring immediate corrective action if needed.
  • Real-Time Temperature Feedback: Minimizes overtreatment or incomplete ablation, standardizing the ablation zone.
  • Ergonomic Stability: Slim handle and multiple insertable lengths ensure stable needle control even in challenging anatomies.