AngioTEN Closure Device

A percutaneous vascular closure system for arterial or venous access sites, enabling secure hemostasis after catheterization or interventional procedures.

AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.

Cyanoacrylate Adhesive Technology

Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.

Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.

By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.

Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.

Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.

  • Heavy calcification, severely diseased artery walls
  • Uncontrolled bleeding or coagulopathy beyond standard care measures
  • Infection at the puncture site

Product Specifications

Specification Detail / Value
Product Name AngioTEN Closure Device
Intended Use Percutaneous vascular closure post-catheterization
Closure Mechanism Suture-mediated or collagen plug
Applicable Access Sites Femoral artery/vein up to 8F–10F introducer sizes
Deployment Method Single-step device insertion and anchor release
Hemostasis Time Typically < 1 minute post-deployment
Sterility Sterile, Single Use
Shelf Life ~2–3 years at 15–25 °C

Ordering & Size Matrix

Access Size (F) Closure Method Deployment Steps Product Code
5–8 Collagen Plug Single ATN-CP-5-8-S
5–8 Suture-Mediated Single ATN-SM-5-8-S
8–10 Collagen Plug Single ATN-CP-8-10-S
8–10 Suture-Mediated Single ATN-SM-8-10-S